Alarmtech MC 340 Magnetic Contact Recessed Mounting Instruction Manual

MC 340 is a versatile magnetic contact produced by Alarmtech, which can be used in alarm and security access control systems for protection of doors, gates and windows against unauthorized opening.


Alarmtech MC 340 Magnetic Contact Recessed Mounting Instruction Manual - cover page
Brand
Alarmtech
Category
sensor
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
505 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
E4E8FA93E2A3C172126D914A09B152B6

About this manual

The Alarmtech MC 340 is a magnetic contact for alarm and security access control systems, used to protect doors, gates and windows against unauthorized opening. It can be recessed or surface-mounted with a range of accessories, including installations on ferromagnetic materials.

The contact consists of a contact part with a reed switch and a magnet part. In the neutral position the reed switch stays closed; opening the monitored object increases the distance to the magnet until the switch opens and activates an alarm. The manual covers mounting, circuit and distance diagrams, operating principle, installation notes, optional resistors and technical data.

What's inside

  • Description
  • Mounting Instructions
  • Circuit Diagram
  • Distance Diagram - Wood
  • Technical Data
  • Operating Principle
  • Installation
  • Resistors (Optional)
  • Distance Table

Specifications

Contact typeForm A, SPST
Switching voltageMax. 48 V DC/AC
Switching currentMax. 500 mA DC/peak AC
Contact ratingMax. 10 W
Cableф 3.4 mm, 4x0.182 mm²
Environmental classIIIA (EN50130-5:2011)
Operating temperature range-40°C to +70°C
Operating humidity rangeMax. 95% r. h.
Housing materialPlastic ABS
Dimensions, contact partф 8 x 26 mm
Dimensions, magnet partф 8 x 26 mm
Security grade2 (EN50131-2-6:2008)
Make distance on woodTyp. 21 mm ±40 %
Break distance on woodTyp. 25 mm ±40 %

Frequently asked questions

How should the contact and magnet be installed?

They should be installed axially, corresponding to each other.

What must be used when installing the MC 340 in a ferromagnetic environment?

An appropriate accessory must be used for installation in a ferromagnetic environment.

What are the two parts of the MC 340?

A contact part with a reed switch and a magnet part.

How can the installation be checked?

Use an ohmmeter to check the electrical connections and test the function of the magnetic contact.