Nuaire BPS V-BC Vertical Boxer Packaged Solution with Basic (BC) Control Installation Manual

This document is the BPS V-BC Vertical Boxer Packaged Solution with Basic (BC) Control Installation Manual.


Nuaire BPS V-BC Vertical Boxer Packaged Solution with Basic (BC) Control Installation Manual - cover page
Brand
NuAire
Category
Air conditioner
Document type
Installation Guide
Language
English
Pages
20
File format
PDF
File size
2.8 MB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
89E7CCAB5AE9D52F7BD6E93332AA807A

About this manual

The BPS V-BC is a Nuaire Boxer Packaged Solution air handling unit with heat recovery. It is manufactured from Aluzinc corrosion resistant steel with 50mm double skinned panels and an anodized aluminium frame, and includes high efficiency centrifugal fans with EC motors, a thermal wheel or plate heat exchanger, G4 pre-filtration, F7 main filtration of the supply air, and M5 filtration of the extract air. The unit is supplemented with the Basic (BC) control platform.

The installation manual covers safety information and symbols, important information, personal protective equipment, introduction, code description, and optional ancillaries. It states that the electrical supply and mains connection must be carried out by a qualified electrician, the unit must be earthed, and it must be isolated from the power supply before removing any covers.

What's inside

  • Safety Information
  • Symbols
  • Important Information
  • Personal Protective Equipment
  • Introduction
  • Code Description
  • Optional Ancillaries

Specifications

Unit constructionAluzinc corrosion resistant steel, 50mm double skinned panels, anodized aluminium frame of thermally-broken design
BS EN 1886 classificationMechanical strength D1; leakage class L1; thermal transmittance T2; thermal bridging TB1
Fan typeHigh efficiency centrifugal fans with EC motors
Heat recoveryThermal wheel or plate heat exchanger
FiltrationG4 pre-filtration, F7 main filtration of supply air, M5 filtration of extract air
Heating optionsLPHW, Electric or Reverse Cycle DX
Cooling optionsChilled Water or Reverse Cycle DX
Unit sizes07, 12, 17, 22, 32 or 42
Control typeBasic (BC) Control

Frequently asked questions

What does BC mean in the BPS V-BC model code?

BC indicates Basic Control in the unit code description.

What should be done before removing any covers?

The unit must be isolated from the power supply before removing any covers.

Who must carry out the electrical supply connection?

The electrical supply and connection of the unit to the mains must be carried out by a qualified electrician.

What gloves are recommended when handling sheet metal components?

Full finger gloves, such as Marigold PU800 or equivalent, are recommended when handling sheet metal components.