This manual contains installation, use, maintenance and inspection instructions for the fixed ladder system.
This manual describes the installation, use, maintenance and inspection of Hailo fixed vertical ladder systems with standard wall brackets. It covers steel, stainless steel and aluminium ladders, ladder connectors and rest platforms, and explains the safety precautions, planning requirements and standards that apply.
The document includes general installation instructions, step-by-step mounting guidance, label and note requirements, maintenance and care procedures, inspection plans and an installation/acceptance report. It also lists the relevant standards and regulations, warranty conditions and the telephone numbers recommended for emergency contact.
| Applicable standards | DIN EN ISO 14122-4, DIN 18799-1 and DIN 14094-1 |
|---|---|
| Angle of inclination | More than 75° to 90° to the horizontal |
| Clearance from ladder rung | 650 mm from the front edge of the ladder rung (600 mm in the case of obstructions) |
| Fall protection height threshold | Required for heights ≥ 3 m per DIN 18799-1 and DIN EN ISO 14122-4 |
| Fall protection above 10 m | Only fall protection according to EN 353-1 is allowed for heights above 10 m with single-section ladders |
| Railing length at exit platforms | Railings of at least 1500 mm in length on both sides |
The fixed ladder systems described in the manual meet DIN EN ISO 14122-4, DIN 18799-1 and DIN 14094-1.
According to DIN 18799-1 and DIN EN ISO 14122-4, fall protection is required for heights of 3 m and above.
Fixed vertical ladders are to be arranged at an angle of inclination of more than 75° to 90° to the horizontal.
The space between the vertical ladder and the surrounding area must be 650 mm from the front edge of the ladder rung, or 600 mm in the case of obstructions.