This file is the TT MIX PRO user manual, which provides detailed instructions on the use, installation, and maintenance of the product.
This user’s manual is the main operating document for technical, maintenance, and operating staff. It describes the purpose, technical details, operating principle, design, and installation of the TT MIX PRO inline mixed-flow fan and all its modifications.
The TT MIX PRO is a mixed-flow inline fan for supply or extract ventilation of premises, designed for connection to air ducts from ø 100 to 315 mm. It is rated for single-phase AC 220-240 V/50 Hz or 220 V/60 Hz mains, continuous operation, and ambient temperatures from +1 °C to +40 °C, with IPX4 ingress protection and Class II electrical rating.
| Air duct diameter | ø 100, 125, 150, 160, 200, 250 and 315 mm |
|---|---|
| Power supply | single-phase AC 220-240 V/50 Hz or 220 V/60 Hz |
| Motor speed | Two speed |
| Ingress protection rating | IPX4 |
| Electrical appliance class | Class II |
| Ambient air temperature | +1 °C to +40 °C |
| Transported air temperature | -25...+60 °C |
The delivery set includes the fan, screws and dowels, a plastic screwdriver for models with a timer, the user’s manual, and a packing box.
The fan is rated for connection to single-phase AC 220-240 V/50 Hz or 220 V/60 Hz power mains.
Yes, the fan is suitable for horizontal or vertical mounting on the floor, wall, or ceiling.
The ingress protection rating against access to hazardous parts and water ingress is IPX4.