This is an operation guide for talent qPCR premix
This operation guide covers the use of TIANGEN FP209 Talent qPCR PreMix (SYBR Green), a ready-to-use quantitative PCR reagent. It lists the materials needed for the experiment and explains how to thaw and mix the 2×Talent qPCR PreMix, 50×ROX Reference Dye, cDNA template, primers and RNase-free ddH2O.
The guide provides reaction mixture tables for 50, 25 and 20 μl systems, tips on pipetting loss compensation, primer concentration optimization and ROX Reference Dye selection for different instruments. It then describes sealing and marking tubes or 96-well plates, brief centrifugation and the qPCR cycling program, including the melting curve stage.
| Reaction system volumes | 50 μl, 25 μl and 20 μl systems |
|---|---|
| Primer final concentration | 0.3 μM, adjustable in the range of 0.2-0.5 μM |
| Initial denaturation | 95°C for 3 min, 1 cycle |
| PCR cycles | 40 cycles of 95°C 5 sec (denaturation) and 60°C 15 sec (annealing/extension) |
| ROX Reference Dye concentration | 5× (e.g. 5 μl ROX/50 μl system) for ABI PRISM 7000/7300/7700/7900HT/StepOne; 1× (e.g. 1 μl ROX/50 μl system) for ABI 7500, 7500 Fast, ViiA 7 and Stratagene Mx3000P/Mx3005P/Mx4000; no need to add for Roche, Bio-Rad and Eppendorf instruments |
The final primer concentration is 0.3 μM, which gives good amplification in most systems. It can be adjusted in the range of 0.2-0.5 μM for further optimization.
It depends on the instrument: use 5× (e.g. 5 μl ROX/50 μl system) for ABI PRISM 7000/7300/7700/7900HT/StepOne, 1× (e.g. 1 μl ROX/50 μl system) for ABI 7500, 7500 Fast, ViiA 7 and Stratagene Mx3000P/Mx3005P/Mx4000, and none for Roche, Bio-Rad and Eppendorf instruments.
Perform an initial denaturation at 95°C for 3 min, then 40 cycles of 95°C for 5 sec and 60°C for 15 sec, followed by melting curve analysis.