Hargrove Hidden Control (HC) Vented Gas Logs Installation and Operation Guide

This manual explains how to safely install and operate Hargrove Hidden Control Vented Gas Logs


Hargrove Hidden Control (HC) Vented Gas Logs Installation and Operation Guide - cover page
Brand
Hargrove
Category
Heater
Document type
Installation Guide
Language
English
Pages
10
File format
PDF
File size
548 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
7115D351B0628F95277DCA7178974843

About this manual

This is Hargrove's installation and operation guide for its vented gas log sets with the Hidden Control (HC) (1T) design, certified to ANSI Z21.60 as a vented decorative appliance for installation in solid-fuel burning fireplaces. It opens with detailed safety information and a pre-installation checklist, then covers damper stop installation, the burner parts list, burner and grate positioning, and the gas connection. Installation and service must be provided by a qualified installer, service agency or the gas supplier.

The guide includes two sizing tables: Table I gives the minimum front width, depth and height plus Btu input ratings for the 18 in., 24 in., 30 in. and 36 in. sets, and Table II gives the minimum permanent free opening based on chimney height and appliance Btu input rating, with a minimum chimney flue diameter of 8 in. It also gives inlet supply pressure limits, cleaning instructions and the damper warning that the damper must be fully open when the logs are operating.

What's inside

  • Important Pre-Installation and Fireplace Safety Information
  • Specifications and Dimensions
  • Table I Minimum Front Width, Depth and Height
  • Table II Minimum Permanent Free Opening
  • Pre-Installation Checklist (Fireplace and Chimney, Gas Line)
  • Damper Stop Installation
  • Burner Parts List
  • Burner and Grate Positioning
  • Gas Connection

Specifications

CertificationANSI Z21.60 vented decorative appliance for installation in solid-fuel burning fireplaces
Minimum fireplace front opening height18 in.
Minimum fireplace depth14 in.
Minimum chimney flue diameter8 in.
Minimum inlet supply pressure5.0 in. water column (natural gas); 11 in. water column (propane gas)
Maximum inlet supply pressure10.5 in. water column (natural gas); 13 in. water column (propane gas)
Gas supply line1/2 in. inside diameter up to 30 feet; 3/4 in. for longer distance

Frequently asked questions

What size fireplace opening do the gas logs require?

Each gas log set needs a minimum 18-inch front opening height and a minimum 14-inch depth, and the width at the front of the fireplace is the critical dimension when choosing the largest set that will fit.

What size should the gas supply line be?

The gas supply line should be 1/2 in. inside diameter up to 30 feet and 3/4 in. for longer distance.

Can solid fuel be burned once the gas logs are installed?

No. Solid fuels shall not be burned in a fireplace where a decorative appliance is installed.

How do I clean the burner?

Shut off the gas supply, remove the burner pan media, and vacuum the burner ports, then replace the media and light the pilot according to the lighting instructions.