Key facts
- Manuals
- 1
- Languages
- EN
- Last added
- 2023-11-03
Featured Hargrove manuals

Hargrove Hidden Control (HC) Vented Gas Logs Installation and Operation Guide
This is Hargrove's installation and operation guide for its vented gas log sets with the Hidden Control (HC) (1T) design, certified to ANSI Z21.60 as a vented decorative appliance for installation in solid-fuel burning fireplaces. It opens with detailed safety information and a pre-installation checklist, then covers damper stop installation, the burner parts list, burner and grate positioning, and the gas connection. Installation and service must be provided by a qualified installer, service agency or the gas supplier.
The guide includes two sizing tables: Table I gives the minimum front width, depth and height plus Btu input ratings for the 18 in., 24 in., 30 in. and 36 in. sets, and Table II gives the minimum permanent free opening based on chimney height and appliance Btu input rating, with a minimum chimney flue diameter of 8 in. It also gives inlet supply pressure limits, cleaning instructions and the damper warning that the damper must be fully open when the logs are operating.
Covers: Important Pre-Installation and Fireplace Safety Information · Specifications and Dimensions · Table I Minimum Front Width, Depth and Height · Table II Minimum Permanent Free Opening · Pre-Installation Checklist (Fireplace and Chimney, Gas Line) · Damper Stop Installation
Latest Hargrove manuals
Hargrove Hidden Control (HC) Vented Gas Logs Installation and Operation Guide
Installation Guide 10 pages · 548 KB · ENInstallation and operation guide for Hargrove Hidden Control (HC) vented gas log sets, covering safety information, sizing tables, parts list, damper stop…
Which document do I need?
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in Hargrove manuals
What size fireplace opening do the gas logs require?
Each gas log set needs a minimum 18-inch front opening height and a minimum 14-inch depth, and the width at the front of the fireplace is the critical dimension when choosing the largest set that will fit.
From: Hargrove Hidden Control (HC) Vented Gas Logs Installation and Operation Guide
What size should the gas supply line be?
The gas supply line should be 1/2 in. inside diameter up to 30 feet and 3/4 in. for longer distance.
From: Hargrove Hidden Control (HC) Vented Gas Logs Installation and Operation Guide