This document is about the Radioactive Effluent Controls Program (ODCM) of Seabrook Station, including the monitoring of liquids and gases, and the Environmental Monitoring Program (REMP).
This manual is the Offsite Dose Calculation Manual (ODCM), Revision 30, effective 6-05-06, for Seabrook Station. It implements Technical Specifications 6.7.6g and 6.7.6h and is divided into Part A, the Radioactive Effluent Controls Program and Radiological Environmental Monitoring Program, and Part B, approved methods for effluent monitor setpoints and offsite dose and concentration estimates.
Part A addresses in-plant monitoring of liquid and gaseous effluents, liquid and gaseous effluent requirements, total dose, environmental monitoring, land use census, interlaboratory comparison, and reports. Part B addresses calculational methods and parameters, setpoint determinations, effluent streams and radiation monitors, and bases for dose calculations. Revisions require an interdisciplinary review and a SORC review.
It implements Technical Specifications 6.7.6g and 6.7.6h.
Part A is the Radioactive Effluent Controls Program and Radiological Environmental Monitoring Program; Part B contains approved methods for setpoints and offsite dose and concentration estimates.
Chemistry, Radiation Protection, I&C, and Operations.
It provides the means to determine that measurable concentrations of radioactive materials released are not significantly higher than expected.