SBK TwinCo 3000 Distribution Station Operating Guide

This is an operating manual for SBK TwinCo 3000 distribution station


SBK TwinCo 3000 Distribution Station Operating Guide - cover page
Brand
SBK
Category
Heater
Document type
User Manual
Language
English
Pages
16
File format
PDF
File size
744 KB
Published
03 November, 2023
Updated
03 November, 2023
MD5 checksum
8D70EAF25893CC0C3F245C3ECB419E96

About this manual

The SBK TwinCo 3000 is a heating circuit distribution station for underfloor heating, made up of a flow distributor and a return distributor and supplemented by a control valve and a pump. It is operated with the SBK Tempus digital controller, which controls the flow temperature either by outside temperature, by boiler flow temperature or as a fixed value controller.

The operating guide covers the station's technical data, its thermal function, the electrical connection of the Tempus control, the available operating modes and control knob settings, the heating curve diagrams for outside-temperature and boiler-temperature controlled operation, and mistake removal. The electrical connection must be made by a qualified electrician.

What's inside

  • Technical data
  • SBK Tempus control overview
  • Thermal functionality of the SBK TwinCo 3000
  • Electric connection of the SBK Tempus control
  • Service and modes of operation
  • Outside temperature controlled flow temperature setting diagram
  • Constant flow temperature setting diagram
  • Function of the rotary knobs SBK Tempus control
  • Mistake removal
  • Accessories

Specifications

Suitable floor surface outputmax. 1,200 l/h (approx. 28,800 kJ) with completely open throttle valve
Preliminary heat temperature, heating systemmin +70 °C
Preliminary heat temperature, floor+20 °C to +50 °C
Middle temperature difference6 to 8 K and approx. 75 W/m²
PumpWilo RS 25/6-3, 3 speed steps (46/67/93 W), IP 42, max. 34 dB(A)
Pump speed area1,100 - 2,200 1/min
Regulator connection voltage230 V ~, 50 Hz, 1.5 VA, IP 42
Regulator ambient conditions-20 °C to +50 °C
Safety temperature limiter switch-offfloor preliminary heat temperature above 60 °C

Frequently asked questions

What happens if the outside sensor is missing or has failed?

The system automatically switches into the constant flow temperature mode.

At what floor temperature does the safety temperature limiter switch off the arrangement?

It switches off the complete arrangement at a floor preliminary heat temperature above 60 °C.

How fast do the valves move?

The valves open and close slowly, in steps of approximately 5 minutes.

Which control knob sets the required flow temperature in constant flow temperature mode?

Control knob C is used to set the required flow temperature; knobs A and B have no function in this mode.