This Spanish user manual covers the Pluvius PRES pressure booster pumps in the 100 W and 260 W versions, imported and distributed by Grifería Roddex S.A. It describes what the pumps are for, their general characteristics, and the technical specifications of both models in a comparison table, followed by performance curves and dimensions.

The manual explains the OFF, AUTO and MANUAL knob positions, the correct and incorrect installation positions, electrical connection safety warnings, and how to purge the pump and give installation examples. A troubleshooting table lists faults, causes and solutions, and a maintenance section describes cleaning the housing and flow sensor, emptying the pump and replacing service parts. This manual is written in Spanish.

What's inside

  • Características generales del producto
  • Especificaciones técnicas
  • Advertencias
  • Especificaciones de seguridad
  • Funciones
  • Instalación y conexión eléctrica
  • Purgado
  • Ejemplos de instalación
  • Posiciones de instalación
  • Identificación de fallas y soluciones

Specifications

Power100 W (0.13 HP) / 260 W (0.35 HP)
Voltage / frequency220 V ~ 50 Hz
Maximum manometric head8.5 m (100 W) / 13 m (260 W)
Maximum flow rate30 L/min (100 W) / 60 L/min (260 W)
Minimum starting pressure0.05 BAR
Port diameter3/4" + nipples, reduction to 1/2"; 1" + nipple, reduction to 3/4"
Pumped liquidClean water, 2 °C to 60 °C
Weight2.8 kg (100 W) / 4.7 kg (260 W)
Capacitor3 mF (100 W) / 5 mF (260 W)
Insulation classClass F
Minimum starting flow1.5 L/min

Frequently asked questions

What is the difference between the PRES 100W and the PRES 260W?

The 100 W model has a maximum head of 8.5 m and a maximum flow of 30 L/min, while the 260 W model reaches 13 m and 60 L/min.

How do I purge the pump?

With the pump plugged in and the knob at AUTO, open a tap, unscrew the purge screw with the correct tool, let all the air escape and then tighten the screw again.

What do the OFF, AUTO and MANUAL positions mean?

OFF means the pump is stopped, AUTO switches it on when a tap is opened and off when it is closed, and MANUAL runs it continuously and is locked with a plastic accessory.

What should I check if the pump does not stop when the tap is closed?

The water flow may be too low or at too little pressure to trigger the flow sensor; it must be greater than 1.5 liters per minute.