This file is the manual of Pluvius PRES 100W/260W, which introduces the features and usage of the product.
This Spanish user manual covers the Pluvius PRES pressure booster pumps in the 100 W and 260 W versions, imported and distributed by Grifería Roddex S.A. It describes what the pumps are for, their general characteristics, and the technical specifications of both models in a comparison table, followed by performance curves and dimensions.
The manual explains the OFF, AUTO and MANUAL knob positions, the correct and incorrect installation positions, electrical connection safety warnings, and how to purge the pump and give installation examples. A troubleshooting table lists faults, causes and solutions, and a maintenance section describes cleaning the housing and flow sensor, emptying the pump and replacing service parts. This manual is written in Spanish.
| Power | 100 W (0.13 HP) / 260 W (0.35 HP) |
|---|---|
| Voltage / frequency | 220 V ~ 50 Hz |
| Maximum manometric head | 8.5 m (100 W) / 13 m (260 W) |
| Maximum flow rate | 30 L/min (100 W) / 60 L/min (260 W) |
| Minimum starting pressure | 0.05 BAR |
| Port diameter | 3/4" + nipples, reduction to 1/2"; 1" + nipple, reduction to 3/4" |
| Pumped liquid | Clean water, 2 °C to 60 °C |
| Weight | 2.8 kg (100 W) / 4.7 kg (260 W) |
| Capacitor | 3 mF (100 W) / 5 mF (260 W) |
| Insulation class | Class F |
| Minimum starting flow | 1.5 L/min |
The 100 W model has a maximum head of 8.5 m and a maximum flow of 30 L/min, while the 260 W model reaches 13 m and 60 L/min.
With the pump plugged in and the knob at AUTO, open a tap, unscrew the purge screw with the correct tool, let all the air escape and then tighten the screw again.
OFF means the pump is stopped, AUTO switches it on when a tap is opened and off when it is closed, and MANUAL runs it continuously and is locked with a plastic accessory.
The water flow may be too low or at too little pressure to trigger the flow sensor; it must be greater than 1.5 liters per minute.