The ODE Mk2/ 70406 ODE PoE Mk2 is a DMX over Ethernet gateway that is compliant with RDM. It supports 1 Universe Ethernet to DMX node (Output mode) and 1 Universe DMX to Ethernet (Input mode). It can be easily set up and updated through any web browser, supports Art-Net, Streaming ACN (sACN), ESP, etc. DMX over Ethernet protocols, also supports RDM over Art-Net (controller), Art-Net 3, HTP/LTP Merging support and IEEE 802.3af PoE (Power over Ethernet).
This manual covers the ENTTEC ODE Mk2 (SKU 70405) and ODE PoE Mk2 (SKU 70406), an Open DMX Ethernet Mk2 RDM compliant DMX over Ethernet Gateway. It lists the box contents, features including 1 Universe Ethernet to DMX output and 1 Universe DMX to Ethernet input, safety notes, and supported protocols Art-Net, Streaming ACN (sACN), and ESP.
It explains basic setup as a factory-configured DHCP DMX output device, discovery and IP address lookup with the NMU app, web-browser configuration, LED status indicators, DMX port settings, refresh rate, HTP/LTP merging, firmware updates, Art-Net send test, 5-pin DMX wiring, and product specifications.
| Input Voltage | 7.5V to 24V DC |
|---|---|
| Max. Power Draw | 6W |
| Max. Current Draw | 800mA |
| Max Output Channels | 1 Universe (512ch) |
| Supported Protocols | ArtNet / sACN / DMX512A / RDM |
| RJ45 Connector | 1 RJ45 connector (10/100 Mbps) |
It is factory configured as a DMX output device listening to the first Art-Net Universe (0x00) and set as a DHCP node.
Use NMU, which will find the ODE on your network and display its IP address, then open the web-interface in a web browser.
Pin 1 is Ground, Pin 2 is Data -, and Pin 3 is Data +.
Latest firmware is available at www.enttec.com/sku/70405 or www.enttec.com/sku/70406, and the correct file must be used for the model.