This guideline introduces the indications, methods, safety and other content of atrial ECG, and provides two atrial ECG operation guides.
This UHL paediatric intensive care guideline describes how to obtain an atrial ECG. It states that atrial ECGs record cardiac activity directly from the surface of the atrium through temporary pacing wires and can clarify ambiguous rhythms alongside a conventional surface ECG.
The guideline lists indications after cardiac surgery, the method for connecting a pacing wire to the V2 lead on a 12-lead ECG machine, and safety rules for handling pacing electrodes. It also includes ward and PICU guidance, example ECGs, training notes, compliance monitoring, references, and key words.
It should be considered in any post-operative patient with a tachycardia where atrial activity is a concern.
Attach the 4 limb leads normally, connect one atrial pacing wire to V2, select leads I, aVF and V2, then make a manual print.
Gloves must be worn when handling pacing electrodes, and pacing wires should not be disconnected from an unstable patient reliant on temporary pacing.