Elkay PIR timer is a wireless lighting control that turns on or off lights by detecting body heat without any operation.
The Elkay PIR timer is designed to replace a single gang light switch and to control lighting, heating and ventilation. It is switched on by the detection of moving body heat within a specified range and switches off after the adjustable time period; a lux level adjustment prevents lighting from being switched on when there is sufficient ambient light.
The fitting and operating instructions cover positioning, mounting and installation, setting the time delay with switches one through four, adjusting the lux level, and operation including the manual override. The document also includes installation notes, outdoor installation guidance for the Elkay energy outdoor range, a 240V AC rating table and a technical helpline.
| Product numbers | 370A-1, 370A-2, 770A-2, 570A-1, 570A-2 |
|---|---|
| Operating voltage | 240V AC |
| Incandescent load | 16A |
| Fluorescent load | 16A |
| Compact fluorescent load | 16A |
| Resistive load | 16A |
| Time delay | 2 mins to 2 hours |
| Compatible accessory plate | Single gang, 25mm deep, British Standard accessory plate |
The time delay can be set from 2 minutes to 2 hours using switches one through four.
Turn off the mains supply for installation.
Press the PIR lens to use the manual override; the lights will be turned on for the set period of time.
The PIR requires approximately 5 minutes to initialise after installation.