North Falcon Energy NF Level Probe Intrinsically Safe Magnetostrictive Probe User Manual

NF Level Probe User Manual introduces the features and characteristics of the magnetic level probes produced by North American Eagle Energy Corporation and their usage instructions


North Falcon Energy NF Level Probe Intrinsically Safe Magnetostrictive Probe User Manual - cover page
Brand
North Falcon Energy
Category
sensor
Document type
User Manual
Language
English
Pages
24
File format
PDF
File size
1.6 MB
Published
02 November, 2023
Updated
02 November, 2023
MD5 checksum
84A8566911CA55FE01390C4E24838CC9

About this manual

This user manual covers the NF level probe family from North Falcon Energy: the NF RDT intrinsically safe magnetostrictive level probe radio data transmitter and the intrinsically safe fuel probes NF 485, NF TTL, NF 420, NF 010 and NF PLM. It gives the device description, electrical characteristics for each type, product marking, probe dimensions, on-tank installation rules, wired connections, wireless setting, maintenance and device return. The probes are intended to be installed by trained service engineers.

The sensor consists of a probe head and a stainless steel probe tube fitted in the tank with a screw-in unit for height adjustment. It operates on the magnetostrictive measuring principle, using a float for product filling level and an additional float for continuous water detection. The devices must be powered through an intrinsically safe barrier, for example North Falcon models ISB-PC or ISB-PR, and the sensor and floats are maintenance free when operated to the manufacturer's specifications.

What's inside

  • Instruction
  • Safety Indication
  • Device Description
  • Electrical Characteristics
  • Product Marking
  • Installation Guide
  • Probe Dimension
  • On Tank Installation
  • Wired Connections
  • Wireless Setting Features and Operations

Specifications

Measurement range200 mm to 12,500 mm
Maximum mechanical length13,000 mm
Measurement accuracy+/- 0.5 mm
Measurement resolution+/- 0.05 mm
Temperature accuracy+/- 0.2 °C
Housing protectionIP68, stainless steel case
Probe shaft materialStainless steel AISI 304 / 316
Supply voltage (NF 485, NF PLM)12 Vdc nominal, 30 V max, through an intrinsically safe barrier
NF RDT battery3.6 Vdc intrinsically safe lithium battery, SAFT LS33600 or EVE ER34615
NF RDT battery lifeUp to 3 years (standard setting)
NF RDT transmission frequency169 MHz
NF RDT transmission powerUp to 200 mW
Maximum transmission distanceUp to 2 km based on the RS485 interface standard
Operating temperature-40 °C to +85 °C
NF 420 output4 to 20 mA, 2 wires, 1 product float
NF 010 output0 to 10 Vdc, 4 wires, 1 product float
ApprovalsOIML-R85 for fixed applications

Frequently asked questions

What is the NF RDT?

It is the radio frequency version of the intrinsically safe magnetostrictive level probe. It is powered by an intrinsically safe lithium battery and transmits with up to 200 mW at 169 MHz.

Can the probe be installed in hazardous areas?

Yes, the magnetostrictive probe can be installed in hazardous areas. The device must be powered and connected with an intrinsically safe barrier such as North Falcon model ISB-PC or ISB-PR, or an equivalent intrinsically safe device.

What water detection limit does the probe have?

For products with a density greater than 0.9 kg/l, water detection cannot take place and the water float must be removed.

Does the sensor need maintenance?

The sensor and associated floats are maintenance free if they are operated according to the manufacturer's specifications and not used for other applications.

Download PDF (1.6 MB)