Installation manual of ALC1275 water sensor
This two-page installation manual from Advanced Power Inc. (solarpumps.com) describes how to install the ALC 1275 water sensor controller, a DC-only device that starts and stops a pump according to water level in a storage tank. It lists the pre-installation checklist, the single tool needed (a Phillips screwdriver), and the main specifications before walking through the numbered installation steps.
The steps cover mounting the sensor under the array on the lower bottom corner of the panel, routing the black sensor wire to the tank, hanging the sensor probes over the tank edge at the desired water height, and extending the wire with direct burial, sunlight resistant 18-2 or smaller gauge wire. The manual also explains the automatic start/stop behavior, the low-voltage disconnect at 11.5 VDC with reconnect at 12 volts, the 75 VDC maximum, the recommended 5 amp inline fuses, and troubleshooting tips for corrosion and damaged connections.
| Minimum Volts DC | 11.5 |
|---|---|
| Maximum Volts DC | 75 |
| Max Amp Load | 5 |
| Sensor Wire Max Length | 1500 FT |
| Included sensor wire | 20 ft |
| Power supply type | DC only |
| Low-voltage disconnect | below 11.5 VDC; reconnects at 12 volts |
| Recommended fuse | 5 amp inline fuse |
It is designed for DC voltage only and must not be used with AC voltage; the minimum is 11.5 volts DC and the maximum is 75 volts DC.
The sensor wire may be extended up to 1500 FT maximum, using only direct burial, sunlight resistant 18-2 or smaller (18-24) gauge wire.
When the water reaches the sensor ends consistently for about 8 seconds, the sensor shuts off power to the pump, and it lets the pump start again after both ends are out of the water for 8 seconds.
Check the connections by removing the lid and inspecting the terminal connections, and check for corrosion or damage at the ends of the sensor wire.