Advanced Power Inc. ALC 1275 Water Sensor Controller Installation Manual

Installation manual of ALC1275 water sensor


Advanced Power Inc. ALC 1275 Water Sensor Controller Installation Manual - cover page
Brand
Advanced Power Inc.
Category
Automation control Equipment
Document type
Installation Guide
Language
English
Pages
2
File format
PDF
File size
398 KB
Published
01 November, 2023
Updated
01 November, 2023
MD5 checksum
6923592FBF73D347A799FBCDE0D00D43

About this manual

This two-page installation manual from Advanced Power Inc. (solarpumps.com) describes how to install the ALC 1275 water sensor controller, a DC-only device that starts and stops a pump according to water level in a storage tank. It lists the pre-installation checklist, the single tool needed (a Phillips screwdriver), and the main specifications before walking through the numbered installation steps.

The steps cover mounting the sensor under the array on the lower bottom corner of the panel, routing the black sensor wire to the tank, hanging the sensor probes over the tank edge at the desired water height, and extending the wire with direct burial, sunlight resistant 18-2 or smaller gauge wire. The manual also explains the automatic start/stop behavior, the low-voltage disconnect at 11.5 VDC with reconnect at 12 volts, the 75 VDC maximum, the recommended 5 amp inline fuses, and troubleshooting tips for corrosion and damaged connections.

What's inside

  • Check List Before Installation
  • Tools Needed
  • Specs
  • Installing Your Controller
  • ALC 1275 Illustration
  • Important Steps When Installing
  • Trouble Shooting

Specifications

Minimum Volts DC11.5
Maximum Volts DC75
Max Amp Load5
Sensor Wire Max Length1500 FT
Included sensor wire20 ft
Power supply typeDC only
Low-voltage disconnectbelow 11.5 VDC; reconnects at 12 volts
Recommended fuse5 amp inline fuse

Frequently asked questions

What voltage can the ALC 1275 water sensor be used with?

It is designed for DC voltage only and must not be used with AC voltage; the minimum is 11.5 volts DC and the maximum is 75 volts DC.

How long can the sensor wire be extended?

The sensor wire may be extended up to 1500 FT maximum, using only direct burial, sunlight resistant 18-2 or smaller (18-24) gauge wire.

What happens when the tank water level reaches the sensor ends?

When the water reaches the sensor ends consistently for about 8 seconds, the sensor shuts off power to the pump, and it lets the pump start again after both ends are out of the water for 8 seconds.

What should I check if the unit will not turn on or off correctly?

Check the connections by removing the lid and inspecting the terminal connections, and check for corrosion or damage at the ends of the sensor wire.