Advanced Power Inc. ALC 1275 Water Sensor Controller Installation Manual
This two-page installation manual from Advanced Power Inc. (solarpumps.com) describes how to install the ALC 1275 water sensor controller, a DC-only device that starts and stops a pump according to water level in a storage tank. It lists the pre-installation checklist, the single tool needed (a Phillips screwdriver), and the main specifications before walking through the numbered installation steps.
The steps cover mounting the sensor under the array on the lower bottom corner of the panel, routing the black sensor wire to the tank, hanging the sensor probes over the tank edge at the desired water height, and extending the wire with direct burial, sunlight resistant 18-2 or smaller gauge wire. The manual also explains the automatic start/stop behavior, the low-voltage disconnect at 11.5 VDC with reconnect at 12 volts, the 75 VDC maximum, the recommended 5 amp inline fuses, and troubleshooting tips for corrosion and damaged connections.
Covers: Check List Before Installation · Tools Needed · Specs · Installing Your Controller · ALC 1275 Illustration · Important Steps When Installing
Latest Advanced Power Inc. manuals
Advanced Power Inc. ALC 1275 Water Sensor Controller Installation Manual
Installation Guide 2 pages · 398 KB · ENInstallation manual for the Advanced Power Inc. ALC 1275 DC water sensor controller, covering wiring, sensor placement, specifications and troubleshooting.
Which document do I need?
Installation Guide
Mounting, wiring and first power-up. Read it before the hardware goes in.
Questions answered in Advanced Power Inc. manuals
What voltage can the ALC 1275 water sensor be used with?
It is designed for DC voltage only and must not be used with AC voltage; the minimum is 11.5 volts DC and the maximum is 75 volts DC.
From: Advanced Power Inc. ALC 1275 Water Sensor Controller Installation Manual
How long can the sensor wire be extended?
The sensor wire may be extended up to 1500 FT maximum, using only direct burial, sunlight resistant 18-2 or smaller (18-24) gauge wire.
From: Advanced Power Inc. ALC 1275 Water Sensor Controller Installation Manual