The Mira Elite ST is a tank-fed (cistern-fed) pumped electric shower from Mira for use where mains water pressure is too low, unreliable or nonexistent. It has an internal pump, separate controls for power selection and temperature/flow adjustment, and is available as 9.8 kW or 10.8 kW models.

This guide covers important safety information, pack contents, specifications, plumbing and electrical installation requirements, installation, commissioning, user instructions, fault diagnosis, maintenance, dimensions, wiring, spare parts and accessories.

What's inside

  • Introduction
  • Important Safety Information
  • Specifications
  • Installation Requirements
  • Installation
  • Commissioning
  • User Instructions
  • Fault Diagnosis
  • Maintenance
  • Dimensions

Specifications

Inlet connection15 mm compression connector with inlet filter; top, bottom or rear entry
Outlet connection1/2 inch BSP male thread for Mira flexible shower hose
Heater power rating (9.8 model)9.8 kW @ 240 V / 45 A (9.0 kW @ 230 V / 40 A)
Heater power rating (10.8 model)10.8 kW @ 240 V / 45 A (9.9 kW @ 230 V / 45 A)
Motor power consumptionapproximately 100 W maximum under normal working conditions
Maximum ambient temperature30 °C
IP ratingIP X4; suitable for installation within zone 1
Operating water pressure0.8 kPa to 100 kPa (0.008 bar to 1 bar)
Terminal block cable sizemaximum 16 mm²
RCD protection30 mA RCD must be fitted
Cistern capacity (illustrated)25 gallon / 113 litre
Standards and approvalsCE marking

Frequently asked questions

What type of water supply does the Mira Elite ST need?

It is designed for gravity-fed supplies providing pressures from 0.8 kPa to 100 kPa and must have its own separate supply from the cistern.

What electrical protection is required?

A 30 mA residual current device (RCD) must be fitted.

Which power ratings are available?

The 9.8 model is 9.8 kW @ 240 V (9.0 kW @ 230 V) and the 10.8 model is 10.8 kW @ 240 V (9.9 kW @ 230 V).

Can the shower be installed in zone 1?

Yes, it is suitable for installation within zone 1 and is rated IP X4.