Mira Element Thermostatic Mixer Installation and User Guide

This manual provides instructions for installing and using the Mira Element thermostatic mixer


Mira Element Thermostatic Mixer Installation and User Guide - cover page
Brand
Mira
Category
Other products
Document type
User Manual
Language
English
Pages
41
File format
PDF
File size
3.3 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
3AF63B0377618CBB1A0A2E72861DAA95

About this manual

The Mira Element thermostatic mixer is a thermostatic shower control with a single control lever for on/off and temperature control; it has no adjustable flow control. A 12 L/min flow regulator is supplied for high pressure systems, and the mixer uses a wax capsule temperature sensing unit with an adjustable maximum temperature stop and inlet filters.

This guide covers safety warnings, pack contents, dimensions, specifications, operating parameters, installation requirements and methods for exposed and built-in models, commissioning, operation, fault diagnosis, maintenance and spare parts.

What's inside

  • Safety Warnings
  • Pack Contents
  • Dimensions
  • Specifications
  • Operating Parameters
  • Installation Requirements
  • Installation Methods
  • Commissioning
  • Operation
  • Maintenance

Specifications

Maximum static pressure10 Bar
Maximum maintained pressure5 Bar
Minimum maintained pressure (gas water heater)1.0 Bar
Minimum maintained pressure (gravity system)0.1 Bar
Factory pre-set (blend) shower temperature43°C
Optimum thermostatic control range35°C - 45°C
Recommended hot supply60°C - 65°C
Minimum differential between hot supply and outlet temperature10°C
Cold water range5°C - 25°C
Thermostatic shut-downHot supply shut off within 2 seconds if cold supply fails
Exposed mixer outlet1/2 inch BSP flat face, bottom
Flow regulator supplied12 L/min for high pressure systems

Frequently asked questions

What is the factory pre-set shower temperature?

The factory pre-set blend shower temperature is 43°C.

What happens if the cold water supply fails?

The thermostat shuts off the hot supply within 2 seconds.

What flow regulator is supplied for high pressure systems?

A 12 L/min flow regulator is supplied.

What is the recommended maximum hot water temperature?

For safety, the maximum hot water temperature is recommended to be limited to 65°C.

Download PDF (3.3 MB)