This document introduces the product features of magnetic switches and is suitable for different scenarios
Aritech magnetic contacts form a circuit between a door and doorframe or between a window and sill. When the alarm system is activated and a window or door is opened, the circuit is broken and an alarm is generated. Each contact consists of two parts: a reed switch and a magnet.
The guide covers surface-mount contacts (pages 3–7), recessed-mount contacts (pages 8–11), overhead contacts (pages 12–13) and special applications (pages 14–15), with tables listing codes, gap, connection, contact type, colour and approval columns. It also gives installation rules of thumb: the gap on steel is approximately half the distance achieved in air, switch and magnet should be spaced at approximately 25% of rated gap in air, and if only one spacer is used it should be mounted under the magnet.
| Contact components | Reed switch and magnet |
|---|---|
| Gap on steel | Approximately 1/2 the distance achieved in air |
| Safety factor spacing | Approximately 25% of rated gap in air |
| Spacer position when only one is used | Under the magnet |
| Recessed contact housing | Cylindrical case |
| Surface-mount mounting | Reed switch and magnet mounted parallel |
A reed switch and a magnet.
The circuit is broken and an alarm is generated.
The gap on steel is approximately half the distance achieved in air, and the guide advises spacing switch and magnet at approximately 25% of rated gap in air for safety factor.
They use the same reed switches as surface-mount contacts but have a cylindrical case and are installed by drilling a hole.