Aritech Magnetic Contacts Product Guide
Aritech magnetic contacts form a circuit between a door and doorframe or between a window and sill. When the alarm system is activated and a window or door is opened, the circuit is broken and an alarm is generated. Each contact consists of two parts: a reed switch and a magnet.
The guide covers surface-mount contacts (pages 3–7), recessed-mount contacts (pages 8–11), overhead contacts (pages 12–13) and special applications (pages 14–15), with tables listing codes, gap, connection, contact type, colour and approval columns. It also gives installation rules of thumb: the gap on steel is approximately half the distance achieved in air, switch and magnet should be spaced at approximately 25% of rated gap in air, and if only one spacer is used it should be mounted under the magnet.
Covers: Surface mount – Wired · Surface mount – Terminal · Recessed mount – Wired · Overhead contacts – Wired · Special applications – Wired · Rules of thumb
Latest Aritech manuals
Aritech Magnetic Contacts Product Guide
Product Leaflet 16 pages · 1.6 MB · ENAritech guide to surface-mount, recessed-mount, overhead and special-application magnetic contacts, with tables of codes, gaps and contact types.
Questions answered in Aritech manuals
What are the two parts of an Aritech magnetic contact?
A reed switch and a magnet.
What happens when an alarmed door or window is opened?
The circuit is broken and an alarm is generated.