Rotork Modbus MFU Option Card Installation Manual for IQ3, SI3, CVA, CMA and K-Range Actuators

This document is about the installation manual of the Modbus MFU option card for Rotork IQ3, SI3, CVA, CMA and K-Range actuators.


Rotork Modbus MFU Option Card Installation Manual for IQ3, SI3, CVA, CMA and K-Range Actuators - cover page
Brand
Rotork
Category
Automation control Equipment
Document type
Installation Guide
Language
English
Pages
64
File format
PDF
File size
2 MB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
37CC5F4490D5AB90D314A9ED4062A9C4

About this manual

The Rotork Modbus MFU Option Card Installation Manual covers the Modbus RTU Actuator Control Mk 3 option card for IQ3, SI3, CVA (firmware CVA1.14 or later), CMA and K-Range actuators. The card uses a 2-wire, half-duplex RS-485 highway and Modbus RTU, operating as a slave in Master/Slave communication mode.

The manual describes fitting the module inside each actuator range, RS-485 highway connections and termination, actuator input and output signals, Modbus communication and database details, configuration registers, and setup, maintenance and troubleshooting. It states that the module firmware version covered is V0050 or later, and the default communication settings are address 247, baud rate 9600, parity None and stop bits 1.

What's inside

  • Introduction
  • Modbus Option Card Properties
  • Fitting the Modbus Module Option Card
  • RS-485 Data Highway, Connections and MFU Setup
  • The Actuator Input and Output Signals
  • Modbus Communication
  • Modbus Database
  • Setting Up and Maintaining the MFU
  • Troubleshooting

Specifications

Communication mediumRS-485 2-wire highway (single or dual), half duplex
ProtocolModbus RTU
Communication modeMaster/Slave; module is a slave
Card typeModbus Mk 3 option card
Default communication settingsAddress 247, baud rate 9600, parity None, stop bits 1
Modbus module firmwareV0050 or later

Frequently asked questions

What protocol does the Rotork Modbus MFU option card use?

The module uses the Modbus RTU protocol.

What are the default communication settings for the module?

The default values are address 247, baud rate 9600, parity None and stop bits 1.

Which Modbus module firmware version does the manual cover?

The manual relates to Modbus module firmware version V0050 or later.

What is the module's role in Modbus communication?

The module is a slave and uses Master/Slave communication mode.