LDH LDH-AAA-FCA-TF-S336 Laser distance sensor Specifications / Operating Manual

LDH-AAA-FCA-TF-S336 laser distance sensor specifications / operating manual, including product certification, use conditions, measurement range, measurement accuracy, light source, response time, pollution degree, supply voltage, current consumption, maximum power dissipation, typical measurement error, analog current output, digital output and other information.


LDH LDH-AAA-FCA-TF-S336 Laser distance sensor Specifications / Operating Manual - cover page
Brand
LDH
Category
sensor
Document type
User Manual
Language
English
Pages
2
File format
PDF
File size
580 KB
Published
31 October, 2023
Updated
31 October, 2023
MD5 checksum
58DEB3E2B4A3358C7168BD8B8F915528

About this manual

The LDH-AAA-FCA-TF-S336 laser distance sensor is certified under ATEX and IECEx for use in potentially explosive atmospheres, including Ex Zones 0, 1, and 2. It uses time-of-flight measurement with a visible red light Class 2 laser and provides results on a 4mA to 20mA analog output and an RS-485 serial interface.

The sensor has a stainless steel 1.4404 housing with IP67 protection and an M42 thread. It operates on +24VDC with 70mA current consumption and works in ambient temperatures from -10°C to +35°C, or up to +50°C in pulse mode. The measurement window must be cleaned carefully if soiled, and the sensor is maintenance-free.

What's inside

  • Technical Data
  • Intended Use
  • Installation prescriptions for Ex hazardous locations
  • General Installation Prescriptions
  • Function
  • Analog current output
  • Serial interface
  • START input
  • Maintenance and durability
  • Safety regulations for Laser devices class 2

Specifications

Measurement range (analog output)0.05m to 30m
Measurement range (digital output)0.05m to 30m
Analog output signal4mA to 20mA
Serial interfaceRS-485
Housing materialStainless steel 1.4404
Light sourceVisible red light laser

Frequently asked questions

What is the measurement range of the sensor?

The measurement range is 0.05m to 30m for both analog and digital outputs.

What analog output signal does the sensor use?

It uses an analog current output signal from 4mA to 20mA.

What is the housing material of the sensor?

The housing is made of stainless steel 1.4404.

Download PDF (580 KB)