This document is the user manual for the HDI series frequency converter. It details the safety precautions for using the frequency converter, product standard specifications, storage and installation, wiring, digital operator instructions, trial running, function list, function description, maintenance and maintenance, fault information and troubleshooting methods, peripheral facilities selection and configuration, appendixes and other content, which can help users use the frequency converter correctly.
This is the Chinese user manual for the HDI series multi-function, high-performance general-purpose adjustable-frequency drive (inverter). It opens with purchase checks and an explanation of the HDI series nameplate, followed by safety precautions to observe before power is applied, while power is on, and during operation. It then gives the product's individual and general specifications, and covers storage, installation site/environment and installation space and orientation.
The remaining sections cover main circuit wiring diagrams, terminal descriptions, basic wiring diagrams and wiring notes; the digital operator; trial run checks and procedures; the function list and function descriptions; maintenance inspection, periodic checks, fault messages and troubleshooting; selection and configuration of peripheral equipment. Appendices give simple application examples and machine outline and mounting dimensions. The manual states that HDI ELECTRONICS CO., LTD. may change the contents without notice. This manual is written in Chinese.
| Nameplate example model | HDI7.5E4L |
|---|---|
| Input | 3-phase 380 V 50 Hz |
| Output | 3-phase 380 V, 17.5 A, 7.5 kW |
| Frequency range | 0.1~400 Hz |
| Voltage class code | 2L = 220 V single-phase; 4L = 380 V three-phase |
| Capacity code | 2.2 means 2.2 kW |
| Series code | E = general type, F = fan/pump type |
Check for transport damage or deformation, and confirm that the package contains one HDI series inverter and one user manual, and that the ordered specification matches the nameplate.
The supply voltage must match the inverter's input specification; the nameplate example shows 3-phase 380 V 50 Hz.
No. The output terminals U, V and W must never be connected to the AC supply.
Cooling performance becomes poorer above 1000 m, so the inverter should be used with a derated rating.