This manual describes the operation and maintenance of the GE 20-1 and GE 20-2 electric inflators
This is the instruction manual for the BRAVO GE 20-1 and GE 20-2 12V electrical inflators. It opens with a warning list and general safety rules for the work area, the battery, the charger and the compressed air, and then gives important charging notes such as the recommended charging temperature, the maximum charging time and the caution not to supply the inflator from an external battery at more than 13 VDC.
The introduction describes the GE 20-2 as a portable, high efficiency electric inflator with a twin cylinder pump that inflates at any pressure between 10 and 1500 mbar, starts with the ON push button and switches off automatically when the set pressure on the gauge is reached. The unit runs on an included battery, can be connected to a cigarette plug or an external 12V battery via alligator clips, and is recharged by a 110-240Vac adaptor or a 12Vdc cigarette plug. A troubleshooting table and an accessories note (partly in Italian) close the document.
| Supply voltage | 12 V DC |
|---|---|
| Pump type | Twin cylinder, high performance pump |
| Pressure range | 10 to 1500 mbar |
| Charger input | 110-240 Vac adaptor |
| Charging time | Up to 8 hours |
| Fuse rating | 30 A |
| Maximum external battery voltage | 13 VDC |
| Recommended charging air temperature | 18°-24°C (65°F and 75°F) |
Charging time may take up to 8 hours.
The GE 20-2 is able to inflate at any pressure between 10 and 1500 mbar.
Replace it with a fuse of the same type, rated 30 A.
The inflator automatically stops and a RED light on the gauge signals the status until it goes off.