Describes the maintenance methods of the flame hood
This document is a supplement to the Cameron hot air balloon maintenance manual, approved under EASA.21J.140 (C593). It covers the Safire burner and supersedes the basic manual where there is a conflict.
It provides maintenance procedures for the Safire burner, including lubrication of valves and handles, liquid and vapour pilot light cleaning, piezo igniter replacement, main burner jet service, crossflow valve adjustment, and a list of repair parts and materials.
| Spark gap | 4-6 mm |
|---|---|
| Main burner jet torque | 17 Nm (12 lb. ft) |
| Whisper valve free movement | approximately 10° |
Spray a little silicone lubricant onto the exposed stem, or apply a light smear of KSP125 grease where the stem exits the housing and operate the valve several times.
Set the electrode tip so a spark of 4-6 mm jumps to the edge of one of the slotted holes in the flame cup.
Burner jets should be tightened to a maximum of 17 Nm (12 lb. ft).