Cameron Safire Burner Hot Air Balloon Maintenance Manual Supplement

Describes the maintenance methods of the flame hood


Cameron Safire Burner Hot Air Balloon Maintenance Manual Supplement - cover page
Brand
Cameron
Category
Other
Document type
Service Manual
Language
English
Pages
8
File format
PDF
File size
96 KB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
5D2648EBDA1F85BDD92841B055749690

About this manual

This document is a supplement to the Cameron hot air balloon maintenance manual, approved under EASA.21J.140 (C593). It covers the Safire burner and supersedes the basic manual where there is a conflict.

It provides maintenance procedures for the Safire burner, including lubrication of valves and handles, liquid and vapour pilot light cleaning, piezo igniter replacement, main burner jet service, crossflow valve adjustment, and a list of repair parts and materials.

What's inside

  • Safire Burner General
  • Fuel System Repairs
  • Lubrication of Main Blast and Pilot Light Valves
  • Whisper Valve Lubrication and Adjustment
  • Liquid Pilot Light
  • Vapour Pilot Light
  • Replacement of the Piezo Igniter
  • Safire Main Burner Jets
  • Crossflow Valve
  • Repair Parts and Materials

Specifications

Spark gap4-6 mm
Main burner jet torque17 Nm (12 lb. ft)
Whisper valve free movementapproximately 10°

Frequently asked questions

How are the main blast and pilot light valves lubricated?

Spray a little silicone lubricant onto the exposed stem, or apply a light smear of KSP125 grease where the stem exits the housing and operate the valve several times.

What spark gap is required for the pilot light igniter?

Set the electrode tip so a spark of 4-6 mm jumps to the edge of one of the slotted holes in the flame cup.

What is the maximum torque for tightening burner jets?

Burner jets should be tightened to a maximum of 17 Nm (12 lb. ft).