Cameron Barton 7000 Series Turbine Flowmeter User Manual

This is a product manual for the Barton 7000 series turbine flowmeters. It includes information such as product specifications, electrical classification, pressure boundary certification, measurement performance, CE markings, etc.


Cameron Barton 7000 Series Turbine Flowmeter User Manual - cover page
Brand
Cameron
Category
Mass Flowmeter
Document type
User Manual
Language
English
Pages
36
File format
PDF
File size
1.2 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
F3FB5B09BD74484EF232CF02E3AE05DD

About this manual

This Cameron user manual covers the Barton 7000 Series turbine flowmeters, including Models 71xx, 72xx, and 73xx for liquid service and Model 74xx for gas service. It is Part No. 9A-11350, Rev. 04, dated August 2012.

The manual provides safety information, specifications, and certifications, then describes unpacking, installation, electrical and flowmeter positioning, routine maintenance, parts replacement, disassembly and assembly, pickup coil checks, troubleshooting, and dimensional drawings.

What's inside

  • Safety Information
  • Introduction
  • Installation and Operation
  • Maintenance
  • Dimensional Drawings
  • Electrical Classification
  • Pressure Boundary Certification
  • Measurement Performance
  • Standard Pickup Coil

Specifications

Linearity (Models 7100, 7200, 7300)+1.0% for 1/4-in. and 3/8-in. sizes
Temperature Range (Models 7100, 7300)-160°F to 850°F (-107°C to 454°C)
Temperature Range (Models 7200, 7400)-425°F to 570°F (-254°C to 299°C)
Pickup Coil Temperature Range-450°F to +450°F (-268°C to +232°C)
Pickup Coil DC Resistance1200 ohms (nominal)
Pickup Coil Inductance450 mh (nominal)
Pickup Coil Dielectric Strength500 VAC rms minimum
Pickup Coil ConnectorMIL-C-5015 (mates with MS31 06-10SL-4S)

Frequently asked questions

Which Barton 7000 Series models are for gas service?

Model 74xx flowmeters are for gas service.

What is the temperature range for Model 7100 and 7300 flowmeters?

Models 7100 and 7300 operate from -160°F to 850°F (-107°C to 454°C).

Can the pickup coil be removed without stopping fluid flow?

Yes, the pickup coil can be removed for troubleshooting without depressurizing the meter or stopping fluid flow.

What bearings do Models 7200 and 7400 feature?

Models 7200 and 7400 feature self-lubricating, precision stainless steel ball bearings.