This is a product manual for the Barton 7000 series turbine flowmeters. It includes information such as product specifications, electrical classification, pressure boundary certification, measurement performance, CE markings, etc.
This Cameron user manual covers the Barton 7000 Series turbine flowmeters, including Models 71xx, 72xx, and 73xx for liquid service and Model 74xx for gas service. It is Part No. 9A-11350, Rev. 04, dated August 2012.
The manual provides safety information, specifications, and certifications, then describes unpacking, installation, electrical and flowmeter positioning, routine maintenance, parts replacement, disassembly and assembly, pickup coil checks, troubleshooting, and dimensional drawings.
| Linearity (Models 7100, 7200, 7300) | +1.0% for 1/4-in. and 3/8-in. sizes |
|---|---|
| Temperature Range (Models 7100, 7300) | -160°F to 850°F (-107°C to 454°C) |
| Temperature Range (Models 7200, 7400) | -425°F to 570°F (-254°C to 299°C) |
| Pickup Coil Temperature Range | -450°F to +450°F (-268°C to +232°C) |
| Pickup Coil DC Resistance | 1200 ohms (nominal) |
| Pickup Coil Inductance | 450 mh (nominal) |
| Pickup Coil Dielectric Strength | 500 VAC rms minimum |
| Pickup Coil Connector | MIL-C-5015 (mates with MS31 06-10SL-4S) |
Model 74xx flowmeters are for gas service.
Models 7100 and 7300 operate from -160°F to 850°F (-107°C to 454°C).
Yes, the pickup coil can be removed for troubleshooting without depressurizing the meter or stopping fluid flow.
Models 7200 and 7400 feature self-lubricating, precision stainless steel ball bearings.