Kolinda Tianyu Real Scene Layout RTK User Manual, introduces the composition, installation, configuration, common function usage of Tianyu Real Scene Layout RTK
This is the first-edition user manual for the Tianyu Real Scene Layout RTK, published by Guangdong Kolida Instrument Co., Ltd. in December 2022. It introduces the main unit, handset and accessories, interfaces, buttons, indicators and receiver operating modes.
The manual describes static survey and RTK operation using an external radio base station or network CORS, then covers common functions including point measurement, point stakeout, result data export, IMU tilt survey, real-scene stakeout, WebUI configuration and firmware upgrade. Appendix A and Appendix B provide technical specifications for the Tianyu RTK and the H6 handset. This manual is written in Chinese.
| Positioning output frequency | 1 Hz to 20 Hz |
|---|---|
| Initialization time | Less than 10 seconds |
| Static measurement accuracy, plane | ±(2.5 mm + 0.5×10⁻⁶D) |
| Static measurement accuracy, elevation | ±(5 mm + 0.5×10⁻⁶D) |
| RTK measurement accuracy, plane | ±(8 mm + 1×10⁻⁶D) |
| RTK measurement accuracy, elevation | ±(15 mm + 1×10⁻⁶D) |
| IMU update rate | 200 Hz |
| Tilt angle | 0° to 60° |
| Dimensions | 131 mm × 80 mm |
| Weight | 800 g |
| Operating temperature | –45°C to +75°C |
| Protection rating | IP68 |
| Battery | 6800 mAh, 7.4 V |
| Data storage | 4 GB internal solid-state storage |
| Real-scene stakeout camera | 2 megapixels |
| Radio frequency | 410–470 MHz |
| Bluetooth | BT4.2 |
In the powered-off state, press and hold the power key; when a beep sounds and all lights turn on, release the key to power on.
After the receiver is powered on, press and hold the power key for more than six seconds until the voice prompt says set working mode, then release.
With the receiver on, press and hold the power key for more than 20 seconds until the voice prompt says factory reset is entered, then release.
Measure the instrument height three times; the difference between the three results must not exceed 3 mm, and the average is used.