KROHNE MFC 400 Mass Flowmeter Signal Converter Technical Data Sheet

MFC 400 series is a high-performance Coriolis mass flow meter converter, which is suitable for a wide range of applications. Including liquid and gas, low-temperature and high-temperature fluids, single-phase and multiphase flow measurement, can be stably and accurately measured mass flow, density and temperature through advanced digital signal processing technology.


KROHNE MFC 400 Mass Flowmeter Signal Converter Technical Data Sheet - cover page
Brand
KROHNE
Category
Mass Flowmeter
Document type
Product Leaflet
Language
Chinese
Pages
32
File format
PDF
File size
2.2 MB
Published
30 October, 2023
Updated
30 October, 2023
MD5 checksum
86AC2926EDF1885EFCECCDE041B7C6EC

About this manual

The KROHNE MFC 400 is a signal converter for Coriolis mass flowmeters. The document states that it was developed according to IEC 61508 and is suitable for SIL 2/3 safety applications depending on the I/O and flow sensor variant. It includes an Entrained Gas Management (EGM) function and NAMUR NE 107 diagnostics, and supports Foundation Fieldbus, Profibus DP/PA, Modbus and HART communication.

The technical data sheet covers product features, options and variants, possible signal converter and flow sensor combinations, measuring principle, technical data, dimensions and weights, installation, and electrical connections. It describes integral and field housing versions as well as inputs/outputs, power supply, materials and ambient conditions. This manual is written in Chinese.

What's inside

  • Product features
  • Options and variants
  • Signal converter / flow sensor combinations
  • Measuring principle
  • Technical data
  • Dimensions and weights
  • Installation
  • Electrical connections
  • Inputs/outputs

Specifications

Measuring principleCoriolis principle
Measured variablesMass flow, density, temperature, volume flow, flow velocity, concentration
Standard power supply100…230 VAC (-15% / +10%), 50/60 Hz
Optional power supply24 VDC (-55% / +30%)
Power consumptionAC: 22 VA; DC: 12 W
Protection classIP66/67 (NEMA 4/4X)
Storage temperature-40…+70°C / -40…+158°F
DisplayGraphical LC display, 256 x 128 pixels, 59 x 31 mm, white backlight
Communication interfacesFoundation Fieldbus, Profibus PA and DP, Modbus, HART
Signal cable lengthMax. 20 m / 65.6 ft

Frequently asked questions

What is the MFC 400?

It is a signal converter for Coriolis mass flowmeters, described in the document as suitable for a very wide range of applications.

Which communication interfaces are available?

The document lists Foundation Fieldbus, Profibus PA and DP, Modbus and HART.

What power supply does the MFC 400 use?

The standard supply is 100…230 VAC (-15% / +10%), 50/60 Hz; a 24 VDC (-55% / +30%) option is also listed.

What is the EGM function?

EGM is an entrained gas management system that enables high-performance continuous measurement at 0...100% entrained gas.

Download PDF (2.2 MB)