This manual introduces the measurement and evaluation of contaminants in hydraulic systems, and provides cleanliness report formats, sampling procedures, common particle sizes, pollution grade recommendations and other information to help users better understand hydraulic system pollution issues
This MP Filtri manual covers fluid condition and contamination monitoring, including particle count analysis, differences between NAS 1638 and AS4059E/F, and sampling procedures.
It also presents cleanliness report formats, NAS 1638, ISO 4406, and SAE AS4059 cleanliness levels, contaminant size information, recommended contamination levels, filtration ratio information, viscosity conversion, water in hydraulic oil, differential pressure evaluation, and filtration particle size. This manual is written in Chinese.
The document states that 70-80% of failures and up to 45% of bearing failures are caused by contaminants in hydraulic oil.
The system should run for at least 30 minutes before sampling.
At least 45 liters of fluid should be flushed back to the sampling container.