Key facts
- Manuals
- 1
- Languages
- ZH
- Last added
- 2023-10-30
Featured MP Filtri manuals

MP Filtri Fluid Cleanliness and Filtration Manual
This MP Filtri manual covers fluid condition and contamination monitoring, including particle count analysis, differences between NAS 1638 and AS4059E/F, and sampling procedures.
It also presents cleanliness report formats, NAS 1638, ISO 4406, and SAE AS4059 cleanliness levels, contaminant size information, recommended contamination levels, filtration ratio information, viscosity conversion, water in hydraulic oil, differential pressure evaluation, and filtration particle size. This manual is written in Chinese.
Covers: Particle count analysis · NAS 1638 and AS4059E differences · Sampling procedure · Cleanliness report format · NAS 1638 cleanliness classification · ISO 4406 cleanliness code
Latest MP Filtri manuals
MP Filtri Fluid Cleanliness and Filtration Manual
Other 32 pages · 1.9 MB · ZHMP Filtri handbook on fluid cleanliness, particle counting, sampling, cleanliness codes, and filtration.
Questions answered in MP Filtri manuals
What share of hydraulic system failures are caused by contaminants in hydraulic oil?
The document states that 70-80% of failures and up to 45% of bearing failures are caused by contaminants in hydraulic oil.
How long should the system run before taking a sample?
The system should run for at least 30 minutes before sampling.