This manual introduces the function features, hardware interfaces, product specifications, communication protocols and module parameter configuration of Zhiqian 32-way network relay controller.
This is the Chinese user manual for the Zhiqian Wulian 32-channel network relay controller, using the ZQWL-IO-1BZRC32 as its example. The controller is described as an industrial-grade IO control board with 32 relay outputs, one Ethernet port, and one RS485 interface; it can be controlled through Modbus TCP/RTU or a custom protocol, or through the company's PC control software.
The manual covers the naming rule and supported models, quick start and hardware preparation, electrical and environmental specifications, relay specifications, interface layout and wiring, configuration software and web configuration, advanced functions such as heartbeat and registration packets, cascading, delayed disconnect and timed control, communication protocols, factory reset and firmware upgrade, application examples, and common troubleshooting. This manual is written in Chinese.
| Relay outputs | 32 channels |
|---|---|
| Ethernet interface | 1 RJ45 port |
| RS485 interface | 1 port |
| Power voltage (12 V models) | 11–13 V DC, typical 12 V |
| Power voltage (24 V models) | 21–25 V DC, typical 24 V |
| Operating current (16 relays on, 12 V models) | 1000 mA |
| Operating current (16 relays on, 24 V models) | 490 mA |
| Operating temperature | -40 to 85 °C |
| Storage temperature | -40 to 85 °C |
| Operating humidity | 5–95%RH |
| Relay output load current | 10 A |
| Default IP address | 192.168.1.253 |
| Default TCP port | 1030 |
| RS485 baud rate | 115200 |
The default IP address is 192.168.1.253.
It has 32 relay outputs.
The controller supports Modbus commands, ASCII control commands, and a custom control protocol.
Up to four clients can connect in TCP server mode.