User manual for 8-channel network relay controller, introducing the product's features, hardware interface, specifications, module parameter configuration and other information.
This is the user manual (V1.1) for the 智嵌物联 (ZQWL) 8-channel network relay controller, an industrial IO control board with 8 opto-isolated digital inputs compatible with NPN and PNP sensors, 8 relay outputs, one Ethernet port and one RS485 port. The manual states that all models in the table of applicable types share the same software functions and differ only in supply voltage, relay brand and housing; the examples use the ZQWL-IO-1CXRC8.
The document walks through hardware preparation, control with the ZQWL network IO configuration software, default parameters, control with a network debugging assistant, product specifications, hardware interfaces and dimensions, parameter configuration by software and web page, advanced features such as heartbeat packets, linkage control, delay-off and timer control, the custom, ASCII and Modbus RTU/TCP protocols, factory reset and firmware upgrade, application examples and troubleshooting. This manual is written in Chinese.
| Supply voltage (12 V models) | 11 V min / 12 V typ / 13 V max |
|---|---|
| Supply voltage (24 V models) | 21 V min / 24 V typ / 25 V max |
| Operating current (all 8 relays on) | 350 mA typical (12 V models) |
| Digital inputs | 8 DI, NPN/PNP compatible |
| Relay outputs | 8 channels, load current selectable from 10 A to 30 A |
| Communication interfaces | 1 Ethernet port, 1 RS485 port |
| I/O count | 8 DI, 8 DO, 1 RS485, 1 RJ45 |
| Operating and storage temperature | -40 to 85 ℃ |
| Operating humidity | 5~95%RH |
| ESD level | Air discharge ±15 kV, contact discharge ±8 kV |
| Default IP address | 192.168.1.253 |
| Default work mode and local port | TCP_SERVER, port 1030 |
| Default RS485 baud rate | 115200, None/8/1 |
| Housing (ZQWL-IO-1CXRC8 type) | Rail mount, 145*90*40 mm (L*W*H) |
The factory default IP address is 192.168.1.253 with subnet mask 255.255.255.0 and gateway 192.168.1.1; the web page user name and password are both admin.
It supports Modbus commands, ASCII control commands and a custom control protocol, and can also be controlled by the company's PC configuration software.
Up to 4 clients can be connected when the device works in TCP server mode.
A 12 VDC @ 1 A power supply is used in the test setup, with VCC to the positive (red) wire and GND to the negative (black) wire.
The device ships in TCP_SERVER mode with local port 1030 and RS485 set to 115200, None/8/1.