VRP-B-CH series valve regulator pilot instruction manual, introduces product usage and maintenance methods
The Becker VRP-B-CH series balanced seat, double-acting pilot provides pressure control when used with a double-acting piston actuated control valve. It measures downstream sensing pressure and positions the double-acting actuator to maintain the desired downstream pressure, with setpoints ranging from 3 psig to 1500 psig.
This manual covers installation, operation, adjustment, and maintenance, along with technical specifications, materials of construction, model number explanation, troubleshooting, parts, and assembly procedures. It states that only those qualified through training or experience should install, operate, or maintain Becker pilots.
| Steady state gas consumption | <10 scfh when bleeding to atmosphere |
|---|---|
| Maximum flow capacity | 850 scfh (24 scmh) |
| Maximum supply pressure | 400 psig (2758 kPa) |
| Maximum supply-discharge differential | 150 psig (1034 kPa) |
| Minimum supply-discharge differential | 50 psig (348 kPa) |
| Operative ambient temperature range | -20°F to 160°F (-29°C to 71°C) |
| Approximate weight | 12 pounds (5.4 kg) |
| Control accuracy | ±0.75% of setpoint |
| Setpoint range | 3 psig to 1500 psig (21 kPa to 10342 kPa) |
| Housing | Meets NEMA 3 classification |
The setpoint range is 3 psig to 1500 psig.
Steady-state gas consumption is less than 10 scfh when bleeding to atmosphere.
Compatible actuators include Becker RPDA and LPDA actuators, as well as other manufacturers' double-acting piston actuators.
Control accuracy is ±0.75% of setpoint.