Emtronix ETA416 Digital IO Expansion and Control Module Data Sheet

Emtronix ETA416 digital IO expansion and control module data sheet, the module supports RS485/RS232 bus, 4-way relay dry contact output, 6-way dry contact input, 8-way TTL level digital I/O


Emtronix ETA416 Digital IO Expansion and Control Module Data Sheet - cover page
Brand
Emtronix
Document type
Datasheet
Language
Chinese
Pages
12
File format
PDF
File size
492 KB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
09B16D745C1ADA39272A3FAA7EF6C984

About this manual

The ETA416 is a digital I/O expansion module based on Emtronix's SBC8xx industrial application board and compliant with the DM5028 expansion module standard. It features 4 relay outputs, 6 isolated dry contact inputs, and 8 TTL-level digital I/O lines with ESD protection. The module uses I2C for control and supports RS485/RS232 serial communication via hardware multiplexing. It is designed for industrial environments with EMC and isolation features.

The module includes detailed pinout descriptions for control signals, relay and dry contact interfaces, and digital I/O ports. Electrical specifications cover operating voltage, temperature ranges, and isolation characteristics. Two variants are available: ETA416-RS485 and ETA416-RS232, differing in serial communication configuration. This manual is written in Chinese.

What's inside

  • Introduction
  • Physical Dimensions
  • Interface Description
  • Control Signal Interface
  • Relay and Dry Contact Interface
  • Digital I/O Interface
  • Electrical Characteristics
  • Ordering Information
  • Technical Support
  • Version History

Specifications

Operating Temperature-10 to 60°C
Storage Temperature-60 to 120°C
Digital I/O Voltage3.3V TTL
IsolationOptocoupler for dry contact inputs/outputs
Serial Interfaces2x RS485/RS232 (hardware multiplexed)

Frequently asked questions

What is the voltage for the digital I/O signals?

The digital I/O signals operate at 3.3V TTL level.

What is the operating temperature range for the ETA416?

The operating temperature range is -10 to 60°C.

How are the relay outputs controlled?

Relay outputs are controlled by low-level signals to close the contacts and high-level signals to release them.

What is the default power supply for the dry contact inputs/outputs?

The default power supply for dry contact inputs/outputs is DC5V, which must be externally provided.