ASAIR AFD4040 Flow Sensor User Manual

AFD4040 flow sensor manual from Aosong, including flow range, repeatability, pressure class, medium temperature, thread type, digital display, linearization, technical parameters, drawing, dimension diagram, wiring diagram, flow formula, model, rated flow, installation and other contents


ASAIR AFD4040 Flow Sensor User Manual - cover page
Brand
ASAIR
Document type
User Manual
Language
Chinese
Pages
11
File format
PDF
File size
1.5 MB
Published
29 October, 2023
Updated
29 October, 2023
MD5 checksum
DEF851F15A391A0785546DA9ACDE28C5

About this manual

This manual provides instructions for installing, wiring, and operating the AFD4040 flow sensor in industrial environments. It includes technical specifications, safety warnings, and maintenance guidelines. The sensor measures flow rates from 5 to 40 L/min with a precision of ±3.0% F.S. and outputs a 4–20mA signal. Proper installation and handling are critical to avoid damage or safety hazards. This manual is written in Chinese.

What's inside

  • Safety Instructions
  • Technical Specifications
  • Installation
  • Wiring Diagram
  • Operation and Calibration
  • Maintenance and Cleaning
  • Disassembly and Handling

Specifications

Flow Range5~40L/min
Pressure Rating10bar (max 16bar)
Medium Temperature-20~100℃
Environmental Temperature-10~65℃
Power Supply18~28VDC
Signal Output3-wire 4~20mA
Accuracy<±3.0% F.S.
Body MaterialPom/SUS304 (stainless steel)

Frequently asked questions

What is the flow range of the AFD4040 sensor?

The flow range is 5 to 40 L/min.

What is the output signal type?

It outputs a 3-wire 4–20mA signal proportional to flow.

What is the maximum pressure rating?

The maximum pressure rating is 16 bar.

What materials is the sensor body made of?

The sensor body is made of Pom and SUS304 (stainless steel).