DTS6606vcn type three-phase four-wire electronic energy meter user manual, which introduces in detail the working principle, model, specifications, main technical parameters, and main functions of the energy meter.
This user manual provides detailed instructions for installing, operating, and troubleshooting the Delixi DTS6606vcn three-phase four-wire electronic energy meter. It covers technical specifications, communication protocols, display functions, wiring diagrams, and safety precautions. The meter complies with GB/T 17215.321-2021 and DL/T 645-2007 standards, and includes features like infrared and RS485 communication, load control, and data storage.
The manual also includes installation guidelines, environmental requirements, fault diagnosis, and warranty information. It emphasizes proper wiring, voltage/current limits, and safety measures to prevent damage or malfunction. The device is designed for residential use and is not suitable for railway, aircraft, or marine applications. This manual is written in Chinese.
| Nominal Voltage | 3×57.7/100V or 3×220/380V |
|---|---|
| Current Specifications | 0.05-0.1(10)A/1(10)A, 0.25-0.5(60)A/5(60)A, 0.6-1.5(80)A/10(80)A, 0.8-2(100)A/10(100)A |
| Accuracy Class | B级 (1级) |
| Communication Protocol | DL/T 645-2007 |
| Default RS485 Baud Rate | 2400bit/s |
| Operating Temperature | -10℃~+55℃ |
| Working Humidity | Yearly average relative humidity ≤75% |
| Voltage Line Power Consumption | ≤2W/10VA |
| Current Line Power Consumption | ≤4.0VA |
| Warranty Period | 36 months |
The default RS485 communication baud rate is 2400bit/s.
The accuracy class is B级 (1级).
The meter supports DL/T 645-2007 communication protocol.
The operating temperature range is -10℃ to +55℃.