Delixi DDSY606 Single-Phase Electronic Prepayment Energy Meter User Manual

User manual for Delixi DDSY606 single-phase prepaid energy meter with LCD, infrared, and RS485 interfaces.


Delixi DDSY606 Single-Phase Electronic Prepayment Energy Meter User Manual - cover page
Brand
德力西
Document type
User Manual
Language
Chinese
Pages
10
File format
PDF
File size
635 KB
Published
02 November, 2026
Updated
02 November, 2026
MD5 checksum
1F06EA85D927B55B7517F96BC37E8A5B

About this manual

This manual covers installation, operation, and technical specifications for the Delixi DDSY606 prepaid energy meter. It supports IC card, infrared, and RS485 communication for prepayment and remote management. The meter complies with GB/T 17215.321-2021 and DL/T 645-2007 standards.

Key features include bidirectional energy measurement, prepaid functionality with alarms and overload protection, and data protection via solid-state memory. This manual is written in Chinese.

What's inside

  • Overview
  • Design Principles
  • Technical Specifications
  • Main Functions
  • LCD Display
  • Usage Operations
  • Installation and Wiring

Specifications

Accuracy ClassB级、A级 (1级、2级)
Communication ProtocolsDL/T 645-2007
Operating Temperature-10℃~+55℃
Dimensions156mm x 109mm ×58mm
Weight0.6kg

Frequently asked questions

What communication methods does the DDSY606 meter support?

It supports IC card, infrared, and RS485 remote communication for prepayment and data management.

How long does the meter's data remain intact after power loss?

Data is preserved for over 10 years using solid-state integrated circuit technology.