This document introduces the features and functions of the Toro T7 series rotor, including adjusting the spray angle, changing the nozzle, and installing the check valve.
This guide covers the Toro T7 Series Rotor sprinkler. It explains how to adjust the right stop and spray arc, position the left stop, pull up the nozzle riser, and change the nozzle to diffuse the spray.
The document also describes the two-way check valve, including how to install it and switch it between position A and position B. Nozzle performance tables list pressure, radius, flow, and precipitation data for standard and low-flow nozzles.
| Right stop adjustment range | 40 º–360º |
|---|---|
| Minimum spray arc | 40 º |
| Maximum spray arc | 360 º |
| Check valve type | two-way check valve |
| Check valve factory position | Position A |
Insert the tool blade into the cap and turn left to decrease arc or right to increase arc.
The check valve is factory installed in position A.
Insert the plastic end of the tool into the cap, twist 1/4 turn, and pull the nozzle riser up.