This document is the user manual of the Turbo Air open display merchandiser, which introduces the product's usage methods, maintenance methods, troubleshooting methods, etc.
This Turbo Air service manual covers the TOM series open display merchandisers, including models TOM-30L through TOM-75L and TOM-30S through TOM-75S. Read the manual completely before installing or operating the equipment.
It provides main component specifications, wiring diagrams, temperature control instructions, part names, and a parts list with order examples for L and S models.
| Compressor electrical rating | 115 V, 60 Hz, 1 Ph |
|---|---|
| Condenser fan motor rating | 115 V, 60 Hz, 1 Ph, 0.8 A, 9 W |
| Water condensing fan motor rating | 115 V, 60 Hz, 1 Ph, 1.1A, 16W |
| Thermostat output | 250 Vac, 1A |
| Ballast rating | 120 V~, 60Hz, 1 A |
| Working temperature | 37°F to 40°F |
The working temperature is from 37°F to 40°F.
It is near the front right hand side underneath the bottom shelf.
The original setting for the control is Normal.
Keep the power switch on before operating this equipment.