The 2AP Gear Drive is an all-weather, two-axis positioning platform designed to point instruments at the sun or at stationary targets. It provides high accuracy, resolution, and repeatability with a payload capacity of 65 kg and torque of 40 Nm. The system can operate as a standalone solar tracker using its embedded microcomputer or as a PC-controlled positioner via the Win2AP software over RS-232.

The manual covers installation, setup, commissioning, operation, maintenance, and troubleshooting. It includes detailed specifications for operating temperature ranges, power requirements, communication parameters, mechanical dimensions, and performance metrics such as accuracy (<0.05°), repeatability (<0.01°), and angular velocity (up to 1.8°/sec). Accessory installation procedures for tripod, mounting plates, sun sensor, and cold weather cover are also provided.

What's inside

  • General Information
  • Technical Data
  • Safety Information
  • Installation and Setup
  • Operation
  • Reference Information
  • Maintenance
  • Solving Problems
  • Appendix I

Specifications

Operating Temperature (Standard)0° to +50°C
Altitude Limit2000 m above sea level (no limit with 24V DC option)
Voltage115/230 VAC (±10%), 60/50 Hz; 24 VDC optional (23-26 VDC)
Power Consumption50 VA standard; 150 VA with heater kit; 200 VA with extreme heater kit
Communication InterfaceRS-232, 3-wire, 8, N, 1, 300 to 9600 baud
Real-Time Clock Accuracy25 ppm (power off), 2 ppm (operating)
Motor TypeStepping motor
Drive MechanismSpur gear primary / double-involute worm final
Accuracy<0.05° (1σ at constant temperature)
Repeatability<0.01° (1σ at constant temperature, same direction)
Resolution0.0025°
Angular VelocityUp to 1.8°/sec (user programmable)
Angular AccelerationUp to 3.6°/sec² (user programmable)
Torque40 Nm
Payload Capacity65 kg balanced
Rotation RangeZenith 90°/210°; Azimuth 540° (360° limit option)
Physical DimensionsLength 35 cm (chassis), 42 cm (with side plates); Width 29 cm; Height 38 cm; Weight 30 kg

Frequently asked questions

What is the operating temperature range of the standard 2AP Gear Drive?

The standard 2AP Gear Drive operates from 0°C to +50°C.

What communication interface does the 2AP use?

The 2AP uses RS-232, 3-wire, 8 data bits, no parity, 1 stop bit at 300 to 9600 baud.

What is the maximum payload the 2AP can carry?

The 2AP can carry a balanced payload of up to 65 kg.

Which software controls the 2AP?

The 2AP is controlled by Win2AP software running on MS Windows.