This document describes the storage devices currently tested by VMware and its storage partners.
This document serves as a compatibility guide for VMware ESX Server 3.0.x, detailing supported storage area network (SAN) environments and storage devices. It outlines the system and virtual machine maximums supported by the software, such as the number of LUNs, HBAs, and virtual disks.
The guide provides specific compatibility matrices for various storage vendors, including 3PAR, Bull, Compellent, Dell, EMC, and others. It covers different configuration levels, such as basic connectivity, multipathing, HBA failover, storage port failover, clustering support, and boot from SAN capabilities.
| Maximum LUNs per system | 256 (128 during install) |
|---|---|
| Maximum HBAs per system | 16 ports |
| Maximum virtual HBAs per virtual machine | 4 |
| Maximum virtual disks per Windows virtual machine | 60 |
| Maximum number of VMFS file systems per server | 256 |
| Maximum disk space per VMFS | 2TB |
| Default max file size for VMFS-3 | 256GB |
| Minimum VMFS-3 volume size | 1.1 GB |
The maximum number of LUNs supported per system is 256, or 128 during installation.
Yes, Microsoft Cluster Service is supported with Windows 2000 SP4 and Windows 2003 RTM, depending on the HBA speed and drivers used.
Yes, the guide indicates that boot from SAN is a supported configuration for ESX Server 3.x hosts.