This document is Clark Pump Rebuild Manual, which details the steps and precautions for rebuilding Clark Pump
This manual provides detailed instructions for technicians to rebuild Clark Pumps, replacing degradable parts like O-rings and seals. It covers disassembly, part replacement, and reassembly procedures for 7%, 10%, and 20% displacement models. Special attention is given to upgrading older units with nickel-bronze fittings to prevent corrosion. Tools and consumables are listed, and torque specifications are provided for final assembly.
| Torque for Cylinder Bolts | 200 inch-pounds |
|---|---|
| Compression Nut Torque | 75 ft. lbs. |
All degradable parts such as O-rings, springs, and seals are replaced, along with any parts showing damage or wear.
Nickel-bronze fittings are used to eliminate crevice corrosion.
The rebuilt pump carries a one-year warranty.