This manual provides instructions for the operation and maintenance of the RPB® PX4 AIR Respirator System.
This manual provides instructions for using the RPB® PX4 AIR, a belt-mounted powered air-purifying respirator (PAPR) designed for non-immediately dangerous atmospheres. It includes setup, operation, safety warnings, and maintenance procedures. The device uses a lithium-ion battery, automatic airflow control, and requires compatible respirator hoods (Nova 3 or Z3). Users must be trained and follow strict safety protocols to avoid injury or death. Replacement filters and components must be genuine RPB® parts to maintain approval.
The manual also details approval standards (EN 12941: 1998 + A1: 2003 + A2: 2008), warranty terms (3 months), and usage limitations, including prohibitions against use in explosive atmospheres or oxygen-deficient environments. It includes troubleshooting and inspection guidelines for daily use and battery maintenance.
| Approval Standard | EN 12941: 1998 + A1: 2003 + A2: 2008 TH2/TH3 P R SL |
|---|---|
| Battery Type | Lithium ion |
The PX4 AIR is approved for use with the Nova 3 Respirator and Z3 Welding Respirator, both compliant with EN 12941: 1998 + A1: 2003 + A2: 2008.
Replace the HE filter if airflow falls below minimum, if the filter media is damaged, or if it becomes wet.