Nitto Kohki DLR5040A-WE Screw Fastening Counter Instruction Manual

This manual introduces the use and precautions of Nitto Kohki's screw fastening counter DLR5040A-WE.


Nitto Kohki DLR5040A-WE Screw Fastening Counter Instruction Manual - cover page
Brand
Nitto Kohki
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
18
File format
PDF
File size
253 KB
Published
27 October, 2023
Updated
27 October, 2023
MD5 checksum
0744712D59BBDDDD07F3E6ACFF5356F5

About this manual

The Nitto Kohki DLR5040A-WE Screw Fastening Counter is a microprocessor-based device designed to detect torque reached signals to ensure accurate screw fastening. It supports counting two types of parts and can be linked with up to 10 units to establish a serial screw fastening system without external controls. The device works in conjunction with specific electric screwdriver models to prevent human fastening errors.

What's inside

  • Safety Precautions
  • Overview
  • Principles of Operation
  • Specifications
  • Installation
  • Setup
  • Operating Instructions
  • Troubleshooting

Specifications

Count range1 to 99
External count input2 inputs (PARTS_A/PARTS_B)
Power supply inputAC100-240V 50/60Hz
Power consumption10W
Dimensions100(W) x 60(H) x 120(D) mm
Mass0.47kg
Compatible screwdriver seriesDLV7000/7100/7200/8000/8100/8200-SPC

Frequently asked questions

What is the count correction function?

It counts only on normal fastening and does not count if the signal comes before the correct timer times out.

How many units can be linked together?

Up to 10 units can be linked together for a serial screw fastening system.

Can the correct timer be set automatically?

Yes, the automatic correct timer function is available to automatically select the minimum value.