This manual introduces the basic installation and quick start guide for MOTORTRONICS VMX series digital solid state soft starters 18-1000A
This guide provides step-by-step instructions for installing and quickly starting up Motortronics VMX Series digital solid state soft starters. It covers receiving, mounting, power connections, control wiring, programming the motor FLA, and setting overload protection. The guide also includes safety warnings and dimensional specifications for proper enclosure installation. The VMX Series uses a six-SCR design for smooth voltage/current ramp control and includes programmable features for starting torque, ramp time, and motor protection.
The guide is designed for users who want to get the unit running with minimal adjustments, using factory presets for common applications. It includes a three-step process for initial setup and a checklist to verify correct installation before start-up. Safety precautions are emphasized, including disconnecting power before servicing and ensuring proper enclosure clearances for cooling.
| Current Range | 18–1000A |
|---|---|
| Starting Current | 350% for 30 seconds, up to 600% for 10 seconds |
| Overload Protection | Solid state electronic overload protection |
| Mounting Clearances | Minimum 1" (25mm) horizontal, 4" (100mm) vertical |
Connect L1, L2, L3 to power lines and T1, T2, T3 to motor; connect control wires and control power; program motor FLA using function F001.
120VAC, with 220VAC as an optional alternative.
4.5 watts per running load amp, for example, 240 x 4.5 = 1080 watts for a 240FLA unit.
Disconnect main power and control power before working on the unit. Use Lock Out tags and ensure the unit is not serviced with voltage applied.