Badger Meter M-5000 Mag Meter Installation and Operation Manual

M-Series® Mag Meter Model M-5000 Installation & Operation Manual


Badger Meter M-5000 Mag Meter Installation and Operation Manual - cover page
Brand
Badger Meter
Category
Industrial Robot
Document type
User Manual
Language
English
Pages
44
File format
PDF
File size
2.3 MB
Published
27 October, 2023
Updated
27 October, 2023
Model
M-5000
MD5 checksum
F3CDDB62610F9CA1723F17E8CD8EBF07

About this manual

The Badger Meter M-5000 is an electromagnetic flow meter designed for fluid metering in various industries, including water, wastewater, food and beverage, pharmaceutical, and chemical applications. The system consists of a detector, which includes the flow tube, isolating liner, and measuring electrodes, and an amplifier responsible for signal processing and display. The manual details the setup of both integral meter mount and remote junction box configurations.

What's inside

  • Safety Precautions
  • System Description
  • Unpacking and Inspection
  • Meter Location and Orientation
  • Pipelines and Fluid Flow
  • Meter/Pipeline Connection
  • Meter Grounding
  • Wiring
  • Power and Battery
  • Programming the M-5000

Specifications

Flow Range0.328 to 32.8 fps (0.1 to 10 m/s)
Sizes1/2-inch to 24 inches (15 mm to 600 mm)
Min. Conductivity≥ 20 micro siemens/cm
Accuracy± 0.50% of rate for velocities greater than 1.64 ft/s
Electrode MaterialsStandard: Alloy C; Optional: 316 stainless steel
Liner MaterialPTFE 1/2 inch to 24 inches, hard rubber 1 inch to 24 inches
Fluid Temperature (Remote Amplifier)PTFE 311°F (155°C); Hard Rubber 178°F (80°C)
Ambient Temperature-4°F to 140°F (-20°C to 60°C)
Meter Housing MaterialCarbon steel welded
FlangesCarbon steel - Standard (ANSI B16.5 Class 150 RF); 316 stainless steel (optional)

Frequently asked questions

What are the straight pipe requirements for the M-5000?

An equivalent of three diameters of straight pipe is required on the inlet side, and two diameters are required on the outlet side.

Can the M-5000 measure flow in any pipeline orientation?

Yes, mag meters can operate accurately in any pipeline orientation and can measure volumetric flow in forward and reverse directions.

What is the minimum conductivity required for the M-5000?

The minimum conductivity required is ≥ 20 micro siemens/cm.

What materials are available for the electrodes?

The standard electrode material is Alloy C, with 316 stainless steel available as an optional material.

Download PDF (2.3 MB)

More Badger Meter Manuals


View all Badger Meter manuals →