Orenco Systems ProSTEP™ Effluent Pump Packages Installation Guide

This manual provides illustrated step-by-step instructions for installing and maintaining a ProSTEP ™ Effluent Pump Package for residential applications.


Orenco Systems ProSTEP™ Effluent Pump Packages Installation Guide - cover page
Brand
Orenco Systems
Document type
Installation Guide
Language
English
Pages
20
File format
PDF
File size
2.8 MB
Published
27 October, 2023
Updated
27 October, 2023
MD5 checksum
26635E2505B771615228419F82B5C89C

About this manual

This guide provides detailed instructions for installing and maintaining ProSTEP™ Effluent Pump Packages in residential wastewater systems. It covers steps from preparing the tank and installing risers to placing the pump vault, splice box, pump, and float switch. Maintenance procedures are also included, such as cleaning filters and testing components. The manual references additional documents for specific parts and includes safety and compatibility notes for different tank types and pipe sizes.

The package includes a control panel, splice box, discharge assembly, Biotube® pump vault, float assembly, and effluent pump. Additional components like risers, lids, and adapters must be ordered separately. The guide emphasizes checking all components upon arrival and following preparation steps to ensure a watertight, hassle-free installation.

What's inside

  • Before You Begin
  • Installation
  • Maintenance
  • Appendixes

Frequently asked questions

What is the maximum water level allowed in the riser during the watertightness test?

Do not allow the water level to rise more than 3 inches (75 mm) into the riser to avoid structural damage to the tank.

What is the maximum number of bends allowed in a wire run according to the National Electrical Code?

The sum of all bends in a wire run is limited to 360 degrees.

How should a pump vault be lowered if the tank is already full of liquid?

Rest the vault on top of the liquid surface and then fill the vault with water from a hose to prevent floating material from entering.