This manual provides illustrated step-by-step instructions for installing and maintaining a ProSTEP ™ Effluent Pump Package for residential applications.
This guide provides detailed instructions for installing and maintaining ProSTEP™ Effluent Pump Packages in residential wastewater systems. It covers steps from preparing the tank and installing risers to placing the pump vault, splice box, pump, and float switch. Maintenance procedures are also included, such as cleaning filters and testing components. The manual references additional documents for specific parts and includes safety and compatibility notes for different tank types and pipe sizes.
The package includes a control panel, splice box, discharge assembly, Biotube® pump vault, float assembly, and effluent pump. Additional components like risers, lids, and adapters must be ordered separately. The guide emphasizes checking all components upon arrival and following preparation steps to ensure a watertight, hassle-free installation.
Do not allow the water level to rise more than 3 inches (75 mm) into the riser to avoid structural damage to the tank.
The sum of all bends in a wire run is limited to 360 degrees.
Rest the vault on top of the liquid surface and then fill the vault with water from a hose to prevent floating material from entering.