The file contains installation instructions.
This document provides installation, operation, and maintenance instructions for the PCD110XP ventilation fan. It includes safety warnings, planning the installation and ductwork, assembly with hanger bars, electrical wiring, and grille installation.
The control box settings are described for high and low airflow, time delay, and humidity sensing. Optional motion-sensing grille operation and sensitivity adjustment are also covered, along with cleaning and motor maintenance notes.
| Model | PCD110XP |
|---|---|
| High-speed airflow range | 80 to 140 CFM |
| Factory high-speed airflow | 110 CFM |
| Time delay adjustment | 5 to 60 minutes |
| Low airflow range | 30 CFM up to the high speed airflow rate |
| Hanger bar span | up to 24 in. |
| Ceiling pitch | up to 12/12 pitch (45 degree angle) |
| Recommended installation height | 7 to 9 feet |
| Motion sensing range | within a 90° cone |
The manual lists the model as PCD110XP.
The time delay can be set from 5 to 60 minutes; after the set time elapses, the fan returns to low speed.
No. The manual states it is not for use in kitchens.
After disconnecting power, rotate the “H” adjustment toward 30% or 80%.