PCD110XP Ventilation Fan Installation and Operation Instructions

The file contains installation instructions.


PCD110XP Ventilation Fan Installation and Operation Instructions - cover page
Category
Other
Document type
User Manual
Language
English
Pages
4
File format
PDF
File size
2.1 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
9011BE71D2BAEF92AD0AFCC24ED6CCD7

About this manual

This document provides installation, operation, and maintenance instructions for the PCD110XP ventilation fan. It includes safety warnings, planning the installation and ductwork, assembly with hanger bars, electrical wiring, and grille installation.

The control box settings are described for high and low airflow, time delay, and humidity sensing. Optional motion-sensing grille operation and sensitivity adjustment are also covered, along with cleaning and motor maintenance notes.

What's inside

  • Cleaning & Maintenance
  • Operation
  • Plan the Installation
  • Assembly Instructions
  • Electrical Wiring
  • Install Grille
  • Humidity Sensor Operation
  • Sensitivity Adjustment
  • Motion Sensor Operation

Specifications

ModelPCD110XP
High-speed airflow range80 to 140 CFM
Factory high-speed airflow110 CFM
Time delay adjustment5 to 60 minutes
Low airflow range30 CFM up to the high speed airflow rate
Hanger bar spanup to 24 in.
Ceiling pitchup to 12/12 pitch (45 degree angle)
Recommended installation height7 to 9 feet
Motion sensing rangewithin a 90° cone

Frequently asked questions

What model is the ventilation fan?

The manual lists the model as PCD110XP.

How long can the fan run at high speed after switch II is turned off?

The time delay can be set from 5 to 60 minutes; after the set time elapses, the fan returns to low speed.

Can the fan be installed in a kitchen?

No. The manual states it is not for use in kitchens.

How is the humidity sensitivity limit adjusted?

After disconnecting power, rotate the “H” adjustment toward 30% or 80%.