This manual provides guidance for design and construction for anyone creating a land disturbance within the City of Hobart, Indiana
The City of Hobart Stormwater Technical Standards Manual 2018 provides guidance for design and construction of stormwater management systems for any land disturbance within the City of Hobart, Indiana. Prepared by Butler Fairman & Seufert, it establishes design standards in a single reference document to ensure quality design and minimize impacts of development on the city's stormwater facilities. The manual applies to new development or redevelopment activities that disturb more than one acre or are part of a larger common plan.
The manual covers applicable policies, runoff rate determination using rational method and TR-55 computer modeling, detention storage volume calculations, storm sewer design standards including pipe sizing and Manning's equation, open channel design requirements for swales and channels, detention design standards, and reference tables for runoff coefficients, rainfall intensities, and depths. It also references Best Management Practices (BMP) and Low Impact Design (LID) manuals for post-construction stormwater quality measures.
The allowable release rate from any development site is 0.2 cubic feet per second per acre.
Storm sewers, inlets, catch basins, and curb and gutters shall be sized for at minimum the peak runoff from a 24-hour, 10-year frequency storm.
Storm sewers shall be sized at a minimum of 12 inches in diameter.
Pipe slopes shall be designed to produce velocities of a minimum of 2.5 feet per second and a maximum of 10 feet per second.