City of Hobart Stormwater Technical Standards Manual 2018

This manual provides guidance for design and construction for anyone creating a land disturbance within the City of Hobart, Indiana


City of Hobart Stormwater Technical Standards Manual 2018 - cover page
Brand
City of Hobart
Document type
Other
Language
English
Pages
86
File format
PDF
File size
3.1 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
448C78C7FBB82BFAE9D960C19DF1BFE5

About this manual

The City of Hobart Stormwater Technical Standards Manual 2018 provides guidance for design and construction of stormwater management systems for any land disturbance within the City of Hobart, Indiana. Prepared by Butler Fairman & Seufert, it establishes design standards in a single reference document to ensure quality design and minimize impacts of development on the city's stormwater facilities. The manual applies to new development or redevelopment activities that disturb more than one acre or are part of a larger common plan.

The manual covers applicable policies, runoff rate determination using rational method and TR-55 computer modeling, detention storage volume calculations, storm sewer design standards including pipe sizing and Manning's equation, open channel design requirements for swales and channels, detention design standards, and reference tables for runoff coefficients, rainfall intensities, and depths. It also references Best Management Practices (BMP) and Low Impact Design (LID) manuals for post-construction stormwater quality measures.

What's inside

  • Applicable Policies
  • Runoff Rate Determination
  • Detention Storage Volumes
  • Storm Sewer Design
  • Open Channel Design
  • Detention Design Standards
  • Runoff Coefficient Tables
  • Rainfall Intensity and Depth Tables
  • Best Management Practices (BMP) Manual
  • Low Impact Design (LID) Manual

Frequently asked questions

What is the allowable release rate for development sites in Hobart?

The allowable release rate from any development site is 0.2 cubic feet per second per acre.

What design storm frequency is required for storm sewer sizing?

Storm sewers, inlets, catch basins, and curb and gutters shall be sized for at minimum the peak runoff from a 24-hour, 10-year frequency storm.

What is the minimum pipe diameter for storm sewers?

Storm sewers shall be sized at a minimum of 12 inches in diameter.

What are the velocity requirements for storm sewer design?

Pipe slopes shall be designed to produce velocities of a minimum of 2.5 feet per second and a maximum of 10 feet per second.