In-Ground Pool/Spa Gas Heater 150-500 Series 51300004201B Installation and Operation Manual

This manual includes detailed installation and operation instructions for the 51300004201B outdoor swimming pool/spa gas heater.


In-Ground Pool/Spa Gas Heater 150-500 Series 51300004201B Installation and Operation Manual - cover page
Category
Water heater
Document type
User Manual
Language
English
Pages
57
File format
PDF
File size
3.4 MB
Published
26 October, 2023
Updated
26 October, 2023
MD5 checksum
6EC07BAD68800D5A280A5810B6593E29

About this manual

This manual covers installation and operation of in-ground pool/spa gas heaters in models 150, 200, 250, 300, 350, 400 and 500, including the ASME variants 250ASME, 400ASME and 500ASME. Opening sections describe heater construction, a wiring connection diagram and a certification and compliance table, followed by safety information on suction entrapment hazards.

The contents run through getting started, locating the heater, altitude of installation, air supply, flue gas venting, gas supply, water piping and electrical connections, then check-out and start-up, control setup, gas testing and water testing. Maintenance and service sections cover water chemistry, winterization, component service, troubleshooting and parts. A specifications table lists gas input, minimum water flow, thermal efficiency, heater width and weight for each model, plus gas operating pressures and orifice drill sizes.

What's inside

  • Getting Started
  • Heater Construction
  • Specifications
  • Wiring Connection Diagram
  • Certification and Compliance
  • Safety Information
  • Installation
  • Locating the Heater
  • Air Supply
  • Flue Gas Venting

Specifications

Electrical supply120 or 240 VAC, 60 Hz, 1-phase, 5.5 A maximum current
Maximum water flow (all models)125 GPM
Combustion and ignitionForced draft combustion with silicon nitride hot surface ignition
Water tubesCupronickel, standard
Fuel typeNatural gas or propane
Gas manifold pressure, natural gas1.8 - 2.2 inwc
Gas inlet pressure, minimum4.5 inwc natural gas, 10.0 inwc propane

Frequently asked questions

What is the maximum water flow for the heater?

The manual states that maximum water flow for all models is 125 GPM, using the integral low loss bypass.

What electrical supply does the heater need?

It requires 120 or 240 VAC, 60 Hz, 1-phase, with 5.5 A maximum current.

Who is allowed to install and service the heater?

Installation and service must be performed by a qualified installer, service agency or the gas supplier.

What should I do if I smell gas?

Do not light any appliance, do not touch electrical switches or use a phone in the building; call your gas supplier from a neighbor's phone, or the fire department if you cannot reach them.

Download PDF (3.4 MB)