This manual includes detailed installation and operation instructions for the 51300004201B outdoor swimming pool/spa gas heater.
This manual covers installation and operation of in-ground pool/spa gas heaters in models 150, 200, 250, 300, 350, 400 and 500, including the ASME variants 250ASME, 400ASME and 500ASME. Opening sections describe heater construction, a wiring connection diagram and a certification and compliance table, followed by safety information on suction entrapment hazards.
The contents run through getting started, locating the heater, altitude of installation, air supply, flue gas venting, gas supply, water piping and electrical connections, then check-out and start-up, control setup, gas testing and water testing. Maintenance and service sections cover water chemistry, winterization, component service, troubleshooting and parts. A specifications table lists gas input, minimum water flow, thermal efficiency, heater width and weight for each model, plus gas operating pressures and orifice drill sizes.
| Electrical supply | 120 or 240 VAC, 60 Hz, 1-phase, 5.5 A maximum current |
|---|---|
| Maximum water flow (all models) | 125 GPM |
| Combustion and ignition | Forced draft combustion with silicon nitride hot surface ignition |
| Water tubes | Cupronickel, standard |
| Fuel type | Natural gas or propane |
| Gas manifold pressure, natural gas | 1.8 - 2.2 inwc |
| Gas inlet pressure, minimum | 4.5 inwc natural gas, 10.0 inwc propane |
The manual states that maximum water flow for all models is 125 GPM, using the integral low loss bypass.
It requires 120 or 240 VAC, 60 Hz, 1-phase, with 5.5 A maximum current.
Installation and service must be performed by a qualified installer, service agency or the gas supplier.
Do not light any appliance, do not touch electrical switches or use a phone in the building; call your gas supplier from a neighbor's phone, or the fire department if you cannot reach them.